Worked example
Example: Illustrative 500000 m3, 60-180 bar, 45 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cavern volume | 500,000 m³ |
| Maximum operating pressure | 18.000 MPa |
| Minimum operating pressure | 6.0000 MPa |
| Gas temperature in the cavern | 45.000 °C |
| Abel–Noble co-volume (about 7.69 × 10⁻³ m³/kg for hydrogen) | 0.007691 m³/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrogen at maximum pressure | 6,204.5 t |
| Cushion gas at minimum pressure | 2,208.7 t |
| Working gas | 3,995.8 t |
| Working gas energy (LHV) | 133.13 GWh |
| Energy per m³ of cavern (kWh) | 266.27 |
| Cushion gas fraction | 35.598 % |
Open this example in the calculator and change any input.
Formula
\(\rho = \frac{p}{RT + bp}, \quad m_{wg} = V\left[\rho(p_{max}) - \rho(p_{min})\right], \quad E = m_{wg}LHV\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Cavern volume | m³ |
| \(p_{max}\) | Maximum operating pressure | Pa |
| \(p_{min}\) | Minimum operating pressure | Pa |
| \(T\) | Gas temperature in the cavern | K |
| \(b\) | Abel–Noble co-volume (about 7.69 × 10⁻³ m³/kg for hydrogen) | m³/kg |
| \(m_{max}\) | Hydrogen at maximum pressure | kg |
| \(m_{cush}\) | Cushion gas at minimum pressure | kg |
| \(m_{wg}\) | Working gas | kg |
| \(E\) | Working gas energy (LHV) | J |
| \(E/V\) | Energy per m³ of cavern (kWh) | - |
| \(m_{cush}/m_{max}\) | Cushion gas fraction | - |
Method and standards
Underground hydrogen inventory.
Where it is used
- Seasonal energy storage planning.
- Hydrogen hub design.
Common mistakes
- Counting the cushion gas as usable.
- Using ideal-gas density at 180 bar.
Assumptions and limits
- Isothermal cavern; pure hydrogen.
References
- Real-gas inventory of a constant-volume store
Questions and answers
How much energy does a salt cavern hold?
A 500,000 m³ cavern cycled between 60 and 180 bar holds about 4,000 t of working hydrogen, roughly 130 GWh, far more than any battery.
What is cushion gas?
Gas left in the cavern at minimum pressure to keep it stable; it is about a third of the maximum inventory and is a capital cost.
What do the defaults represent?
An illustrative 500,000 m³ salt cavern between 60 and 180 bar at 45 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8