Worked example
Example: Illustrative 70 C, lambda 2, 110 kPa, dry inlet. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air stoichiometry | 2.0000 - |
| Exit air pressure (absolute) | 110.00 kPa |
| Cell (exit air) temperature | 70.000 °C |
| Inlet air relative humidity | 0 % |
| Inlet air temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet water-to-dry-air mole ratio | 0 |
| Exit water vapour partial pressure | 20.860 kPa |
| Saturation pressure at the cell temperature | 31.201 kPa |
| Exit relative humidity | 66.857 % |
Open this example in the calculator and change any input.
Formula
\(P_w = \frac{2 + \psi\lambda/y_{O_2}}{1 + \lambda(1 + \psi)/y_{O_2}}P_{exit}, \quad \psi = \frac{P_{w,in}}{P_{in} - P_{w,in}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\lambda\) | Air stoichiometry | - |
| \(P_{exit}\) | Exit air pressure (absolute) | Pa |
| \(T\) | Cell (exit air) temperature | K |
| \(\phi_{in}\) | Inlet air relative humidity | - |
| \(T_{in}\) | Inlet air temperature | K |
| \(\psi\) | Inlet water-to-dry-air mole ratio | - |
| \(P_w\) | Exit water vapour partial pressure | Pa |
| \(P_{sat}\) | Saturation pressure at the cell temperature | Pa |
| \(\phi\) | Exit relative humidity | - |
Method and standards
Cathode water balance.
Where it is used
- PEM stack humidification design.
- Diagnosing drying or flooding.
Common mistakes
- Ignoring inlet humidity in hot humid climates.
- Using the stoichiometric air flow.
Assumptions and limits
- All product water evaporated; uniform exit state.
References
- Cathode water balance of a PEM fuel cell
Questions and answers
Why does exit humidity matter?
PEM membranes conduct protons only when wet; too dry and resistance rises, too wet and liquid water floods the electrodes.
How can a dry cell be made wetter?
Lower the air flow (stoichiometry), raise the pressure, run cooler, or humidify the inlet air with water recovered from the exhaust.
What do the defaults represent?
An illustrative cell at 70 °C, air at twice stoichiometry, exit at 110 kPa, with dry inlet air.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 4