Worked example
Example: Illustrative 20 buses, 250 km. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vehicles | 20.000 - |
| Distance per vehicle per day | 250.00 km |
| Hydrogen use per 100 km (kg) | 8.0000 - |
| Electrolyser system specific energy | 55.000 kWh/kg |
| Electrolyser operating hours per day | 20.000 h |
| Days of storage | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrogen per day | 400.00 kg |
| Electrolyser power | 1.1000 MW |
| Electricity per day | 22.000 MWh |
| Hydrogen storage | 800.00 kg |
Open this example in the calculator and change any input.
Formula
\(m_d = \frac{Ndc}{100}, \quad P_e = \frac{m_de}{t_{op}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Vehicles | - |
| \(d\) | Distance per vehicle per day | m |
| \(c\) | Hydrogen use per 100 km (kg) | - |
| \(e\) | Electrolyser system specific energy | J/kg |
| \(t_{op}\) | Electrolyser operating hours per day | s |
| \(t_s\) | Days of storage | - |
| \(m_d\) | Hydrogen per day | kg |
| \(P_e\) | Electrolyser power | W |
| \(E_d\) | Electricity per day | J |
| \(m_s\) | Hydrogen storage | kg |
Method and standards
Fleet hydrogen balance.
Where it is used
- Bus and truck depot hydrogen projects.
- Refuelling station sizing.
Common mistakes
- Forgetting compression energy.
- Sizing storage without refuelling peaks.
Assumptions and limits
- Daily average demand.
References
- Fleet hydrogen balance
Questions and answers
How much hydrogen does a bus use?
About 7–10 kg per 100 km for a 12 m fuel cell bus, so 250 km a day needs about 20 kg.
Why run the electrolyser long hours?
A high utilisation spreads its capital cost; storage then buffers the difference between steady production and refuelling peaks.
What do the defaults represent?
An illustrative 20 buses running 250 km a day at 8 kg per 100 km, an electrolyser at 55 kWh/kg running 20 h a day and two days of storage.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8