Worked example
Example: Illustrative 10 MW PEM, 2 A/cm2, 3000 cm2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Electrolyser power | 10.000 MW |
| Cell voltage | 1.9000 V |
| Current density | 2.0000 A/cm² |
| Active area per cell | 3,000.0 cm² |
| Maximum cells per stack | 250.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cell (stack) current | 6,000.0 A |
| Cells needed | 878.00 |
| Stacks | 4.0000 |
| Total active area | 263.40 m² |
| Stack voltage with full stacks | 418.00 V |
| Power per active area | 37.965 kW/m² |
Open this example in the calculator and change any input.
Formula
\(I = iA_c, \quad N = \frac{P}{V_cI}, \quad n_s = \left\lceil\frac{N}{N_{max}}\right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Electrolyser power | W |
| \(V_c\) | Cell voltage | V |
| \(i\) | Current density | A/m² |
| \(A_c\) | Active area per cell | m² |
| \(N_{max}\) | Maximum cells per stack | - |
| \(I\) | Cell (stack) current | A |
| \(N\) | Cells needed | - |
| \(n_s\) | Stacks | - |
| \(A_{tot}\) | Total active area | m² |
| \(V_{stack}\) | Stack voltage with full stacks | V |
| \(P/A\) | Power per active area | W/m² |
Method and standards
Stack sizing.
Where it is used
- Electrolyser plant layout and power supply design.
- Comparing technologies.
Common mistakes
- Mixing A/cm² and A/m².
- Forgetting rectifier voltage limits.
Assumptions and limits
- Uniform cells; constant current density.
References
- Series stack arithmetic
Questions and answers
Why do PEM electrolysers use high current density?
Thin membranes and compact cells allow 2 A/cm² or more, reducing expensive catalyst-coated area per MW, at some cost in efficiency.
Why split into several stacks?
Stack voltage and cell count are limited by manufacturing, sealing and DC supply voltage; large plants use many stacks in parallel.
What do the defaults represent?
An illustrative 10 MW PEM electrolyser at 1.9 V and 2 A/cm² with 3,000 cm² cells and up to 250 cells per stack.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8