Worked example
Example: Illustrative 55 + 2.5 kWh/kg, 1 %, 50 % fuel cell. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Electrolysis system specific energy | 55.000 kWh/kg |
| Compression and storage energy | 2.5000 kWh/kg |
| Storage and handling losses of hydrogen | 1.0000 % |
| Reconversion efficiency (LHV; fuel cell or turbine) | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Round-trip efficiency | 28.683 % |
| Electricity in per unit out | 3.4864 |
| Hydrogen per MWh returned | 60.027 kg |
| Power-to-hydrogen efficiency (LHV) | 57.945 % |
Open this example in the calculator and change any input.
Formula
\(\eta_{RT} = \frac{LHV(1 - l_s)\eta_g}{e_{el} + e_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(e_{el}\) | Electrolysis system specific energy | J/kg |
| \(e_c\) | Compression and storage energy | J/kg |
| \(l_s\) | Storage and handling losses of hydrogen | - |
| \(\eta_g\) | Reconversion efficiency (LHV; fuel cell or turbine) | - |
| \(\eta_{RT}\) | Round-trip efficiency | - |
| \(E_{in}/E_{out}\) | Electricity in per unit out | - |
| \(m_{H_2}\) | Hydrogen per MWh returned | kg |
| \(\eta_{P2H}\) | Power-to-hydrogen efficiency (LHV) | - |
Method and standards
Storage chain efficiency.
Where it is used
- Long-duration storage studies.
- Comparing storage technologies.
Common mistakes
- Mixing HHV-based electrolyser and LHV-based fuel cell efficiencies.
- Forgetting compression energy.
Assumptions and limits
- Steady average efficiencies.
References
- Energy chain efficiency of hydrogen storage
Questions and answers
What round-trip efficiency does hydrogen storage give?
About 25–40 %: electrolysis about 60–70 %, compression a few per cent, reconversion 40–60 %.
Why consider it then?
Hydrogen can be stored in tanks or salt caverns for months at low cost per MWh, which batteries cannot do economically.
What do the defaults represent?
An illustrative chain: 55 kWh/kg electrolysis, 2.5 kWh/kg compression, 1 % losses and a 50 % fuel cell.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8