Steam Trap Survey: Annual Loss from Failed Traps

Annual steam and money lost from failed-open and leaking steam traps found in a survey, from counts, loss per trap, hours and steam cost.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textile

Inputs

Examples: 32 faulty trapsSmall plant

From an orifice estimate at the line pressure or the trap maker.

Results

Survey a few times a year; trap failures typically run at several per cent of the population annually.

Steam lost per year390.00t
Cost per year858,000
Payback of repairs (months)0.78322

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 32 faulty traps. The inputs, in the units selected above:

InputValue
Traps failed open (blowing)12.000 -
Loss per failed-open trap25.000 kg/h
Traps leaking20.000 -
Loss per leaking trap6.0000 kg/h
Hours per year8,000.0 h
Steam cost per tonne2,500.0 -
Repair or replacement cost per trap9,000.0 -

Applying the formula below gives:

ResultValue
Steam lost per year3,360.0 t
Cost per year8,400,000
Payback of repairs (months)0.41143

Open this example in the calculator and change any input.

Formula

\(m = (n_f\dot m_f + n_l\dot m_l)t, \quad C = \frac{m}{1000}\,c, \quad t_{pb} = \frac{12\,(n_f + n_l)\,C_r}{C}\ \text{months}\)

Variables

Symbol Meaning SI unit
\(n_f\) Traps failed open (blowing) -
\(\dot m_f\) Loss per failed-open trap kg/s
\(n_l\) Traps leaking -
\(\dot m_l\) Loss per leaking trap kg/s
\(t\) Hours per year s
\(c\) Steam cost per tonne -
\(C_r\) Repair or replacement cost per trap -
\(m\) Steam lost per year kg
\(C\) Cost per year -
\(t_{pb}\) Payback of repairs (months) -

Method and standards

Sum of losses.

Where it is used

  • Steam system audits.
  • Maintenance budgets.

Common mistakes

  • Assuming all failed traps blow full bore.
  • Ignoring failed-closed traps.

Assumptions and limits

  • Average loss rates; the steam cost c is per tonne, so the mass in kg is divided by 1 000.
  • With no cost lost, the payback is not shown.

References

  • Loss = Σ n × loss rate × hours

Questions and answers

12 blowing at 25 kg/h and 20 leaking at 6 kg/h for 8000 h?

3,360 t of steam, 8,400,000 a year; repairs pay back in about 0.4 months.

Loss per trap?

Depends on orifice size and pressure; see the steam leak calculator.

Failed closed?

No steam lost but condensate backs up, causing water hammer and lost heating.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.