FireCADCalc

Lighting Retrofit Saving and Payback

Energy, cost and CO₂ saving from replacing light fittings with more efficient ones, and the simple payback, from fitting counts, wattages, hours and prices.

Inputs

Examples: 400 fittings 72 to 36 WHigh bays 400 to 150 W

Results

Check that the new fittings still give the required illuminance (see the lumen method).

Energy saved per year146.40MWh
Cost saved per year1,171,200
Simple payback (years)0.61475
CO₂ avoided per year105.41t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 400 fittings 72 to 36 W. The inputs, in the units selected above:

InputValue
Number of fittings400.00 -
Old fitting power (with gear)0.072000 kW
New fitting power0.036000 kW
Operating hours per year4,000.0 h
Electricity price per kWh8.0000 -
Installed cost per new fitting1,800.0 -
Grid factor (kg CO₂ per kWh)0.72000 -

Applying the formula below gives:

ResultValue
Energy saved per year57.600 MWh
Cost saved per year460,800
Simple payback (years)1.5625
CO₂ avoided per year41.472 t

Open this example in the calculator and change any input.

Formula

\(\Delta E = n(P_0 - P_1)t, \quad t_{pb} = \frac{n C_f}{\Delta E\, c}\)

Variables

Symbol Meaning SI unit
\(n\) Number of fittings -
\(P_0\) Old fitting power (with gear) W
\(P_1\) New fitting power W
\(t\) Operating hours per year s
\(c\) Electricity price per kWh -
\(C_f\) Installed cost per new fitting -
\(EF\) Grid factor (kg CO₂ per kWh) -
\(\Delta E\) Energy saved per year J
\(\Delta C\) Cost saved per year -
\(t_{pb}\) Simple payback (years) -
\(\Delta m\) CO₂ avoided per year kg

Method and standards

Energy difference.

Where it is used

  • Plant, office and street lighting.
  • Energy audits.

Common mistakes

  • Lamp watts without gear.
  • Ignoring illuminance.

Assumptions and limits

  • Same hours before and after. With no saving the payback is not shown.

References

  • ΔE = n (P₀ − P₁) t

Questions and answers

400 fittings from 72 W to 36 W, 4000 h a year?

57,600 kWh, 460,800 a year; payback 1.6 years.

Old wattage?

Include the ballast or driver losses.

Controls?

Occupancy and daylight controls cut hours too.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.