FireCADCalc

CO₂ Saving from Fuel Switching

Annual CO₂ before and after switching fuels for the same useful heat, from each fuel's emission factor per GJ and the boiler efficiency on each.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Diesel to natural gasCoal to natural gas

From your inventory guide (e.g. IPCC defaults: diesel about 74, natural gas about 56, coal 90–100).

Results

Biomass CO₂ is usually reported as biogenic (often counted as zero); follow your reporting rules.

CO₂ on the old fuel23,073t
CO₂ on the new fuel12,467t
CO₂ saved per year10,607t
Reduction45.969%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Diesel to natural gas. The inputs, in the units selected above:

InputValue
Useful heat per year60,000 GJ
Old fuel emission factor (kg CO₂/GJ of fuel)74.100 -
Efficiency on the old fuel (same CV basis as EF₁)86.000 %
New fuel emission factor (kg CO₂/GJ)56.100 -
Efficiency on the new fuel (same CV basis as EF₂)90.000 %

Applying the formula below gives:

ResultValue
CO₂ on the old fuel5,169.8 t
CO₂ on the new fuel3,740.0 t
CO₂ saved per year1,429.8 t
Reduction27.656 %

Open this example in the calculator and change any input.

Formula

\(m_i = \frac{Q}{\eta_i}EF_i, \quad \Delta m = m_1 - m_2\)

Variables

Symbol Meaning SI unit
\(Q\) Useful heat per year J
\(EF_1\) Old fuel emission factor (kg CO₂/GJ of fuel) -
\(\eta_1\) Efficiency on the old fuel (same CV basis as EF₁) -
\(EF_2\) New fuel emission factor (kg CO₂/GJ) -
\(\eta_2\) Efficiency on the new fuel (same CV basis as EF₂) -
\(m_1\) CO₂ on the old fuel kg
\(m_2\) CO₂ on the new fuel kg
\(\Delta m\) CO₂ saved per year kg
\(x\) Reduction -

Method and standards

Emission factor method.

Where it is used

  • Decarbonisation roadmaps.
  • Boiler fuel studies.

Common mistakes

  • GCV with NCV-based factors.
  • Ignoring efficiency change.

Assumptions and limits

  • Same useful heat.
  • Each efficiency on the same calorific-value basis as its emission factor (IPCC factors are per GJ of NCV, so use NCV-based efficiencies); mixing GCV and NCV errs by 5–11 %.

References

  • CO₂ = (Q/η) × EF per GJ of fuel (IPCC Guidelines tier 1 approach)

Questions and answers

60,000 GJ of heat moving from diesel to natural gas?

From 5,170 to 3,740 t a year.

Why include efficiency?

Fuel burnt, not heat delivered, emits the CO₂.

Factors on NCV or GCV?

IPCC factors are per GJ on NCV; keep the basis consistent.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.