FireCADCalc

Compressed Air: Saving from Lowering Generation Pressure

Compressor power saving from lowering the discharge pressure, from the polytropic work ratio, with the extra saving from reduced leakage at lower pressure.

Thermal power plantProcess steam and utilities

Inputs

Examples: 8 to 7 bar g, 160 kW7 to 6 bar g, 75 kW

Results

Check that every user still gets its minimum pressure after line losses.

Saving in specific work8.1851%
Saving from lower leakage1.8719%
Power saved7.4279kW
Cost saved per year356,537

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 to 7 bar g, 160 kW. The inputs, in the units selected above:

InputValue
Suction (atmospheric) pressure1.0132 bar
Present discharge pressure (absolute)9.0132 bar
New discharge pressure (absolute)8.0132 bar
Polytropic index1.3000 -
Present compressor input power160.00 kW
Share of air lost to leaks25.000 %
Hours per year7,000.0 h
Electricity price per kWh8.0000 -

Applying the formula below gives:

ResultValue
Saving in specific work6.7592 %
Saving from lower leakage2.7737 %
Power saved14.953 kW
Cost saved per year837,347

Open this example in the calculator and change any input.

Formula

\(x_w = 1 - \frac{(p_n/p_a)^{(n-1)/n} - 1}{(p_2/p_a)^{(n-1)/n} - 1}, \quad x_l = x_L\left(1 - \frac{p_n}{p_2}\right)\)

Variables

Symbol Meaning SI unit
\(p_a\) Suction (atmospheric) pressure Pa
\(p_2\) Present discharge pressure (absolute) Pa
\(p_n\) New discharge pressure (absolute) Pa
\(n\) Polytropic index -
\(P\) Present compressor input power W
\(x_L\) Share of air lost to leaks -
\(t\) Hours per year s
\(c\) Electricity price per kWh -
\(x_w\) Saving in specific work -
\(x_l\) Saving from lower leakage -
\(\Delta P\) Power saved W
\(\Delta C\) Cost saved per year -

Method and standards

Polytropic work.

Where it is used

  • Compressor house energy audits.
  • Pressure set-point reviews.

Common mistakes

  • Gauge pressures in the ratio.
  • Ignoring pressure drop to users.

Assumptions and limits

  • Constant air demand.
  • Single-stage polytropic work: for two-stage machines with intercooling the work changes less with pressure, so the saving is slightly overstated.

References

  • Polytropic specific work ∝ (p₂/p₁)^((n−1)/n) − 1; choked leak flow ∝ upstream absolute pressure

Questions and answers

From 8 to 7 bar g on a 160 kW compressor with 25 % leaks?

Work falls about 6.8 % and leaks 2.8 %: roughly 15 kW saved.

Rule of thumb?

Often quoted as 6–8 % per bar; this calculates it from your pressures.

Unregulated users?

Some take more air at higher pressure; lower pressure saves there too.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.