Worked example
Example: 8 to 7 bar g, 160 kW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Suction (atmospheric) pressure | 1.0132 bar |
| Present discharge pressure (absolute) | 9.0132 bar |
| New discharge pressure (absolute) | 8.0132 bar |
| Polytropic index | 1.3000 - |
| Present compressor input power | 160.00 kW |
| Share of air lost to leaks | 25.000 % |
| Hours per year | 7,000.0 h |
| Electricity price per kWh | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saving in specific work | 6.7592 % |
| Saving from lower leakage | 2.7737 % |
| Power saved | 14.953 kW |
| Cost saved per year | 837,347 |
Open this example in the calculator and change any input.
Formula
\(x_w = 1 - \frac{(p_n/p_a)^{(n-1)/n} - 1}{(p_2/p_a)^{(n-1)/n} - 1}, \quad x_l = x_L\left(1 - \frac{p_n}{p_2}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_a\) | Suction (atmospheric) pressure | Pa |
| \(p_2\) | Present discharge pressure (absolute) | Pa |
| \(p_n\) | New discharge pressure (absolute) | Pa |
| \(n\) | Polytropic index | - |
| \(P\) | Present compressor input power | W |
| \(x_L\) | Share of air lost to leaks | - |
| \(t\) | Hours per year | s |
| \(c\) | Electricity price per kWh | - |
| \(x_w\) | Saving in specific work | - |
| \(x_l\) | Saving from lower leakage | - |
| \(\Delta P\) | Power saved | W |
| \(\Delta C\) | Cost saved per year | - |
Method and standards
Polytropic work.
Where it is used
- Compressor house energy audits.
- Pressure set-point reviews.
Common mistakes
- Gauge pressures in the ratio.
- Ignoring pressure drop to users.
Assumptions and limits
- Constant air demand.
- Single-stage polytropic work: for two-stage machines with intercooling the work changes less with pressure, so the saving is slightly overstated.
References
- Polytropic specific work ∝ (p₂/p₁)^((n−1)/n) − 1; choked leak flow ∝ upstream absolute pressure
Questions and answers
From 8 to 7 bar g on a 160 kW compressor with 25 % leaks?
Work falls about 6.8 % and leaks 2.8 %: roughly 15 kW saved.
Rule of thumb?
Often quoted as 6–8 % per bar; this calculates it from your pressures.
Unregulated users?
Some take more air at higher pressure; lower pressure saves there too.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.