FireCADCalc

Core Loss by the Steinmetz Equation with Eddy Current Part

Hysteresis loss by the Steinmetz equation and classical eddy current loss of a laminated core, per kilogram and for the whole core, at a frequency and flux density.

Inputs

Examples: Illustrative 0.27 mm GO steel core at 50 Hz, 1.5 TMotor lamination 0.5 mm at 60 Hz400 Hz aircraft transformer, 0.1 mm

Accepted: 0.1 to 1,000,000 Hz
Accepted: 0.001 to 3 T
Accepted: 0 to 10
Accepted: 1 to 3
Accepted: 0.001 to 10 mm
Accepted: 1 to 1,000 µΩ·cm
Accepted: 1,000 to 10,000 kg/m³
Accepted: 0.001 to 1,000,000 kg

Results

Steinmetz found hysteresis loss per cycle grows as B̂ⁿ with n ≈ 1.6–2, so the loss per kilogram is k_h·f·B̂ⁿ. Eddy currents in a thin lamination with sinusoidal flux give the classical loss π²d²f²B̂²/(6ρ_eρ_m) per kilogram. Measured loss exceeds the sum by an 'excess' (anomalous) part from domain wall motion, so fit k_h and n to the steel's published loss curve; thinner laminations and higher-silicon steels cut the eddy part.

Hysteresis loss (W/kg)2.1262
Classical eddy current loss (W/kg)0.94210
Total specific core loss (W/kg)3.0683
Core loss of the whole core92.048W

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 0.27 mm GO steel core at 50 Hz, 1.5 T. The inputs, in the units selected above:

InputValue
Frequency50.000 Hz
Peak flux density1.5000 T
Hysteresis coefficient (W/kg at 1 Hz, 1 T)0.012000 -
Steinmetz exponent1.8000 -
Lamination thickness0.27000 mm
Steel resistivity48.000 µΩ·cm
Steel density7,650.0 kg/m³
Core mass450.00 kg

Applying the formula below gives:

ResultValue
Hysteresis loss (W/kg)1.2448
Classical eddy current loss (W/kg)0.18369
Total specific core loss (W/kg)1.4285
Core loss of the whole core642.84 W

Open this example in the calculator and change any input.

Formula

\(p_h = k_hf\hat B^n, \quad p_e = \frac{\pi^2d^2f^2\hat B^2}{6\rho_e\rho_m}\)

Variables

Symbol Meaning SI unit
\(f\) Frequency 1/s
\(\hat B\) Peak flux density T
\(k_h\) Hysteresis coefficient (W/kg at 1 Hz, 1 T) -
\(n\) Steinmetz exponent -
\(d\) Lamination thickness m
\(\rho_e\) Steel resistivity Ω·m
\(\rho_m\) Steel density kg/m³
\(m\) Core mass kg
\(p_h\) Hysteresis loss (W/kg) -
\(p_e\) Classical eddy current loss (W/kg) -
\(p\) Total specific core loss (W/kg) -
\(P_{core}\) Core loss of the whole core W

Method and standards

Core loss.

Where it is used

  • Transformer and motor core loss estimates.
  • Comparing lamination grades and thicknesses.

Common mistakes

  • Using RMS flux density instead of peak.
  • Applying the classical eddy term to thick or solid cores (skin effect).

Assumptions and limits

  • Sinusoidal flux; lamination thin compared with the skin depth.

References

  • Steinmetz hysteresis law and classical eddy current loss

Questions and answers

Why does loss rise faster than frequency?

Eddy current loss grows with the square of frequency, hysteresis loss only linearly.

Why is measured loss higher than the sum?

Domain wall motion adds an excess loss not captured by the classical eddy formula.

What do the defaults represent?

An illustrative grain-oriented 0.27 mm transformer steel core of 450 kg at 50 Hz and 1.5 T.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.