FireCADCalc

PV Module Driving a Resistive Load: Operating Point

Operating voltage, current and power of a PV module connected directly to a resistive load, from an ideal single-diode I-V curve, compared with its maximum power.

Thermal power plant

Inputs

Examples: Illustrative 72-cell module at 45 C into 3 ohmMatched load near R_mpDim light: I_sc 2 A, V_oc 41 V, 10 ohm

Accepted: 0.01 to 30 A
Accepted: 0.5 to 200 V
Accepted: 1 to 200
Accepted: 1 to 2
Accepted: -40 to 90 °C
Accepted: 0.01 to 10,000 Ω

Results

Ideal single-diode curve I = I_sc − I₀(e^(V/N_s nV_t) − 1) with I₀ from V_oc; operating point where the curve meets I = V/R. Series and shunt resistance are neglected, so the fill factor is slightly optimistic. A maximum power point tracker keeps the load at R_mp as irradiance changes.

Operating voltage36.439V
Operating current9.1097A
Power delivered0.33195kW
Maximum power of the curve0.33341kW
Utilisation of available power99.561%
Load resistance for maximum power4.1781Ω

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 72-cell module at 45 C into 3 ohm. The inputs, in the units selected above:

InputValue
Short-circuit current9.5000 A
Open-circuit voltage44.000 V
Cells in series72.000 -
Diode ideality factor1.2000 -
Cell temperature45.000 °C
Load resistance3.0000 Ω

Applying the formula below gives:

ResultValue
Operating voltage28.460 V
Operating current9.4866 A
Power delivered0.26998 kW
Maximum power of the curve0.33341 kW
Utilisation of available power80.977 %
Load resistance for maximum power4.1781 Ω

Open this example in the calculator and change any input.

Formula

\(I = I_{sc} - I_0\left(e^{V/(N_snV_t)} - 1\right), \quad I_0 = \frac{I_{sc}}{e^{V_{oc}/(N_snV_t)} - 1}, \quad I = \frac{V}{R}\)

Variables

Symbol Meaning SI unit
\(I_{sc}\) Short-circuit current A
\(V_{oc}\) Open-circuit voltage V
\(N_s\) Cells in series -
\(n\) Diode ideality factor -
\(T_c\) Cell temperature K
\(R\) Load resistance Ω
\(V\) Operating voltage V
\(I\) Operating current A
\(P\) Power delivered W
\(P_{mp}\) Maximum power of the curve W
\(P/P_{mp}\) Utilisation of available power -
\(R_{mp}\) Load resistance for maximum power Ω

Method and standards

PV and load matching.

Where it is used

  • Direct PV water heating and DC motors.
  • Teaching maximum power point tracking.

Common mistakes

  • Assuming the module always delivers its rated power.
  • Ignoring temperature effects on V_oc.

Assumptions and limits

  • Ideal diode; uniform irradiance; no series or shunt resistance.

References

  • Ideal single-diode PV characteristic and load line

Questions and answers

Why does a direct resistive load waste PV power?

The load line crosses the I-V curve at the maximum power point only at one irradiance; at other light levels the operating point moves away, which is why MPPT controllers exist.

What resistance gives maximum power?

R_mp = V_mp/I_mp at the current irradiance and temperature, about 4–5 Ω for a typical 72-cell module in full sun.

What do the defaults represent?

An illustrative 72-cell module (I_sc 9.5 A, V_oc 44 V) at 45 °C feeding a 3 Ω heating element.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.