PV Cell Temperature from NOCT and Temperature-corrected Efficiency

Cell temperature of a PV module from ambient temperature, irradiance and NOCT, with an optional wind correction, and the module efficiency and output there.

Process steam and utilities

Inputs

Examples: Rajasthan summer noon 42 C, 1,000 W/m2, NOCT 44 C, 4 m/s windCold clear day 0 C, 900 W/m2, still air 0.5 m/s

Accepted: -43.15 to 56.85 °C
Accepted: 0 to 1,500 W/m²
Accepted: 26.85 to 66.85 °C
Accepted: 0 to 30 %
Accepted: 50 to 100 %
Accepted: 0 to 20 m/s
Accepted: 1 to 30 %
Accepted: 0 to 0.01
Accepted: 0.1 to 10 m²

Results

NOCT is measured at 800 W/m², 20 °C ambient and 1 m/s wind with the module open-circuited. The efficiency term (1 − η/τα) is small; the linear temperature coefficient is the usual data-sheet model for crystalline silicon.

Cell temperature28.844°C
Rise above ambient28.844K
Module efficiency at the cell temperature19.693%
Module output301.30W

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Rajasthan summer noon 42 C, 1,000 W/m2, NOCT 44 C, 4 m/s wind. The inputs, in the units selected above:

InputValue
Ambient temperature42.000 °C
Irradiance on the module1,000.0 W/m²
Nominal operating cell temperature (data sheet)44.000 °C
Module efficiency at the operating point (first estimate)20.000 %
Transmittance-absorptance (about 0.9)90.000 %
Wind correctionCorrect for wind speed
Wind speed4.0000 m/s
Module efficiency at 25 °C STC21.000 %
Power temperature coefficient (per K, e.g. 0.0035)0.003400 -
Module area2.0000 m²

Applying the formula below gives:

ResultValue
Cell temperature52.606 °C
Rise above ambient10.606 K
Module efficiency at the cell temperature19.029 %
Module output380.58 W

Open this example in the calculator and change any input.

Formula

\(T_c - T_a = (T_{NOCT} - 20)\frac{G_T}{800}\left(1 - \frac{\eta_c}{\tau\alpha}\right)\ \left[\times\frac{9.5}{5.7 + 3.8V}\right]\)

\(\eta = \eta_{ref}[1 - \beta_{ref}(T_c - 25)]\)

Variables

Symbol Meaning SI unit
\(T_a\) Ambient temperature K
\(G_T\) Irradiance on the module W/m²
\(T_{NOCT}\) Nominal operating cell temperature (data sheet) K
\(\eta_c\) Module efficiency at the operating point (first estimate) -
\((\tau\alpha)\) Transmittance-absorptance (about 0.9) -
\(\text{wind}\) Wind correction -
\(V\) Wind speed m/s
\(\eta_{ref}\) Module efficiency at 25 °C STC -
\(\beta_{ref}\) Power temperature coefficient (per K, e.g. 0.0035) -
\(A\) Module area m²
\(T_c\) Cell temperature K
\(T_c - T_a\) Rise above ambient K
\(\eta\) Module efficiency at the cell temperature -
\(P\) Module output W

Method and standards

NOCT energy balance scaling of module temperature.

Where it is used

  • PV yield in hot climates.
  • String voltage checks at maximum cell temperature.

Common mistakes

  • Using ambient temperature as cell temperature.
  • Using the NOCT power rating as STC.

Assumptions and limits

  • Open-rack mounting; roof-integrated modules run hotter.

Questions and answers

Why does cell temperature matter?

Crystalline silicon loses about 0.3–0.5 % of power per kelvin; cells run 20–40 K above ambient in full sun.

Where do I find NOCT and the temperature coefficient?

On the module data sheet; NOCT is typically 42–48 °C and the power coefficient −0.30 to −0.45 %/K.

What do the defaults represent?

An illustrative case: Rajasthan summer noon 42 C, 1,000 W/m2, NOCT 44 C, 4 m/s wind. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 23.3, eqs. 23.3.3 and 23.3.4 and Example 23.3.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.