FireCADCalc

PV Inverter Weighted Efficiency (European and CEC)

European and Californian (CEC) weighted efficiencies of a PV inverter from its efficiency curve at part loads, the figures used to compare inverters.

Thermal power plant

Inputs

Examples: Illustrative string inverterCentral inverter, flat curveOlder transformer inverter

Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 50 to 100 %

Results

European weights 0.03/0.06/0.13/0.10/0.48/0.20 at 5/10/20/30/50/100 % load (a cloudy central-European irradiance profile); CEC weights 0.04/0.05/0.12/0.21/0.53/0.05 at 10/20/30/50/75/100 % (sunnier climate). Use efficiencies at the nominal DC voltage.

European weighted efficiency94.560%
CEC weighted efficiency94.991%
Peak efficiency of the points entered95.500%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative string inverter. The inputs, in the units selected above:

InputValue
Efficiency at 5 % load92.000 %
Efficiency at 10 % load95.000 %
Efficiency at 20 % load97.000 %
Efficiency at 30 % load97.600 %
Efficiency at 50 % load97.900 %
Efficiency at 75 % load97.800 %
Efficiency at 100 % load97.500 %

Applying the formula below gives:

ResultValue
European weighted efficiency97.322 %
CEC weighted efficiency97.630 %
Peak efficiency of the points entered97.900 %

Open this example in the calculator and change any input.

Formula

\(\eta_{EU} = 0.03\eta_5 + 0.06\eta_{10} + 0.13\eta_{20} + 0.10\eta_{30} + 0.48\eta_{50} + 0.20\eta_{100}\)

\(\eta_{CEC} = 0.04\eta_{10} + 0.05\eta_{20} + 0.12\eta_{30} + 0.21\eta_{50} + 0.53\eta_{75} + 0.05\eta_{100}\)

Variables

Symbol Meaning SI unit
\(\eta_{5}\) Efficiency at 5 % load -
\(\eta_{10}\) Efficiency at 10 % load -
\(\eta_{20}\) Efficiency at 20 % load -
\(\eta_{30}\) Efficiency at 30 % load -
\(\eta_{50}\) Efficiency at 50 % load -
\(\eta_{75}\) Efficiency at 75 % load -
\(\eta_{100}\) Efficiency at 100 % load -
\(\eta_{EU}\) European weighted efficiency -
\(\eta_{CEC}\) CEC weighted efficiency -
\(\eta_{max}\) Peak efficiency of the points entered -

Method and standards

Weighted inverter efficiency.

Where it is used

  • Comparing inverter offers.
  • Inputs to PV loss budgets.

Common mistakes

  • Using peak efficiency in yield estimates.
  • Mixing efficiencies measured at different DC voltages.

Assumptions and limits

  • Weights fixed by convention; one DC voltage.

References

  • European and CEC weighted inverter efficiency

Questions and answers

Why weight the efficiency?

Inverters spend much of the year at part load; a weighted figure reflects the energy actually converted better than the peak efficiency.

Which weighting should I use?

European for cloudier climates and CEC for sunny ones; for a yield study use the full efficiency curve at the site.

What do the defaults represent?

An illustrative string inverter efficiency curve peaking near 97.9 % at half load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.