Worked example
Example: Illustrative 540 W over grass. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Front-side irradiance | 0.90000 kW/m² |
| Global horizontal irradiance reaching the ground | 0.80000 kW/m² |
| Ground albedo (grass 0.2, sand 0.3, white gravel or snow 0.5–0.8) | 25.000 % |
| Rear view and shading factor | 55.000 % |
| Bifaciality factor of the module | 70.000 % |
| Front-side rating at STC | 0.54000 kW |
| Power temperature coefficient (per K) | -0.003500 - |
| Cell temperature | 45.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rear-side irradiance | 0.11000 kW/m² |
| Bifacial gain φG_r/G_f | 8.5556 % |
| Equivalent front irradiance | 0.97700 kW/m² |
| Module output | 0.49065 kW |
| Output if monofacial | 0.45198 kW |
Open this example in the calculator and change any input.
Formula
\(G_r = \rho_gF_rG_h, \quad BG = \frac{\varphi G_r}{G_f}, \quad P = P_{STC}\frac{G_f + \varphi G_r}{1000}\left[1 + \gamma(T_c - 25)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(G_f\) | Front-side irradiance | W/m² |
| \(G_h\) | Global horizontal irradiance reaching the ground | W/m² |
| \(\rho_g\) | Ground albedo (grass 0.2, sand 0.3, white gravel or snow 0.5–0.8) | - |
| \(F_r\) | Rear view and shading factor | - |
| \(\varphi\) | Bifaciality factor of the module | - |
| \(P_{STC}\) | Front-side rating at STC | W |
| \(\gamma\) | Power temperature coefficient (per K) | - |
| \(T_c\) | Cell temperature | K |
| \(G_r\) | Rear-side irradiance | W/m² |
| \(BG\) | Bifacial gain φG_r/G_f | - |
| \(G_{eq}\) | Equivalent front irradiance | W/m² |
| \(P\) | Module output | W |
| \(P_{mono}\) | Output if monofacial | W |
Method and standards
Bifacial gain estimate.
Where it is used
- Comparing monofacial and bifacial modules.
- Ground treatment decisions under trackers.
Common mistakes
- Using the albedo as the gain.
- Ignoring rear shading by torque tubes and rails.
Assumptions and limits
- Lumped rear factor; uniform rear irradiance.
References
- Rear-side irradiance and bifacial gain
Questions and answers
How much extra does a bifacial module make?
Typically 5–10 % a year over grass and up to 15–20 % over white gravel, sand or snow on raised trackers.
What limits the rear gain?
Low mounting height, close rows, shading by the structure, and dark ground all reduce the light reaching the back.
What do the defaults represent?
An illustrative 540 W bifacial module at 900 W/m² on the front, 800 W/m² global horizontal, grass-like albedo 0.25, rear factor 0.55, bifaciality 0.70, 45 °C cell.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 7