Worked example
Example: 50 kW in, 2 kW stator loss, 3 % slip, 0.5 kW friction, 1 500 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Stator input power | 50.000 kW |
| Stator losses (copper and iron) | 2.0000 kW |
| Slip | 3.0000 % |
| Friction and windage loss | 0.50000 kW |
| Synchronous speed | 1,500.0 rpm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air-gap (rotor input) power | 48.000 kW |
| Rotor copper loss s P_g | 1.4400 kW |
| Mechanical power developed (1 − s) P_g | 46.560 kW |
| Shaft output | 46.060 kW |
| Efficiency | 92.120 % |
| Torque developed P_g / ω_s | 305.58 N·m |
| Shaft torque | 302.30 N·m |
Open this example in the calculator and change any input.
Formula
\(P_g = P_{in} - P_s, \quad P_{cu,r} = s P_g, \quad P_m = (1 - s) P_g\)
\(T_d = \frac{P_g}{2\pi N_s}, \quad \eta = \frac{P_m - P_{fw}}{P_{in}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{in}\) | Stator input power | W |
| \(P_{s}\) | Stator losses (copper and iron) | W |
| \(s\) | Slip | - |
| \(P_{fw}\) | Friction and windage loss | W |
| \(N_s\) | Synchronous speed | 1/s |
| \(P_g\) | Air-gap (rotor input) power | W |
| \(P_{cu,r}\) | Rotor copper loss s P_g | W |
| \(P_m\) | Mechanical power developed (1 − s) P_g | W |
| \(P_{out}\) | Shaft output | W |
| \(\eta\) | Efficiency | - |
| \(T_d\) | Torque developed P_g / ω_s | N·m |
| \(T_{sh}\) | Shaft torque | N·m |
Method and standards
Power stages of the induction motor.
Where it is used
- Electrical examinations.
- Understanding motor losses.
Common mistakes
- Using rotor speed for developed torque.
- Subtracting rotor loss from input directly.
Assumptions and limits
- Steady running.
- There is no separate stray-load-loss input (IEC 60034-2-1): add stray load losses to the stator losses P_s (or to P_fw) so they are counted.
References
- Induction machine power flow P_g : P_cu : P_m = 1 : s : (1 − s) (textbook)
Questions and answers
A motor takes 50 kW with 2 kW stator loss at 3 % slip. What is the rotor copper loss?
Air-gap power 48 kW; rotor copper loss 0.03 × 48 = 1.44 kW; mechanical power 46.56 kW.
What is the shaft torque at 1500 rpm synchronous?
With 0.5 kW friction, 302 N·m at 1455 rpm.
Why does slip cost efficiency?
A share s of the air-gap power is always lost in the rotor.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.