Worked example
Example: 220 V, 40 A, 0.25 Ω, 1 000 rpm; then 60 A. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Supply voltage | 220.00 V |
| Armature current | 40.000 A |
| Armature resistance | 0.25000 Ω |
| Speed at that current | 1,000.0 rpm |
| New armature current | 60.000 A |
Applying the formula below gives:
| Result | Value |
|---|---|
| Back EMF V − I_a R_a | 210.00 V |
| Power developed E_b I_a | 8.4000 kW |
| Torque developed | 80.214 N·m |
| Back EMF at the new current | 205.00 V |
| Speed at the new current (constant flux) | 976.19 rpm |
Open this example in the calculator and change any input.
Formula
\(E_b = V - I_a R_a, \quad P_d = E_b I_a, \quad T = \frac{P_d}{2\pi N}, \quad \frac{N_2}{N_1} = \frac{E_{b2}}{E_{b1}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Supply voltage | V |
| \(I_a\) | Armature current | A |
| \(R_a\) | Armature resistance | Ω |
| \(N_1\) | Speed at that current | 1/s |
| \(I_{a2}\) | New armature current | A |
| \(E_b\) | Back EMF V − I_a R_a | V |
| \(P_d\) | Power developed E_b I_a | W |
| \(T\) | Torque developed | N·m |
| \(E_{b2}\) | Back EMF at the new current | V |
| \(N_2\) | Speed at the new current (constant flux) | 1/s |
Method and standards
DC machine voltage and torque equations at constant flux.
Where it is used
- Electrical examinations.
- Old DC drives and cranes.
Common mistakes
- Using rpm in the torque formula.
- Applying constant flux to series motors.
Assumptions and limits
- Constant flux; no brush drop. Shunt and separately excited motors only: in a series motor the flux follows the armature current, so the speed relation differs.
References
- DC machine equations E_b = V − I_a R_a
- N ∝ E_b / Φ (textbook)
Questions and answers
What is the back EMF of a 220 V motor taking 40 A with 0.25 Ω armature?
210 V; it develops 8.4 kW, 80.2 N·m at 1000 rpm.
What speed at 60 A?
976 rpm: the speed falls with the back EMF.
Why does speed fall so little?
The armature drop is small against the supply voltage.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.