FireCADCalc

Zener Diode Shunt Regulator: Series Resistor and Power

Series resistor, Zener and resistor dissipation and the minimum Zener current of a Zener shunt regulator from the supply range, Zener voltage and load current.

Inputs

Examples: Illustrative: 5.1 V Zener, 11-14 V supply, 20 mA load, 5 mA minimum3.3 V reference at 5 mA from 4.5-5.5 V12 V Zener, 18-30 V supply, 50 mA load

Accepted: 0.5 to 1,000 V
Accepted: 0.5 to 1,000 V
Accepted: 0.5 to 500 V
Accepted: 0 to 10,000 mA
Accepted: 0.01 to 1,000 mA

Results

R_s = (V_in,min − V_Z)/(I_L + I_Z,min). The Zener must absorb the whole current when the load is disconnected at maximum input; choose a Zener rated for at least twice P_Z and use the next lower standard resistor value.

Series resistor (largest that still regulates)171.43Ω
Resistor dissipation at maximum input0.028233W
Zener current at maximum input and no load12.833mA
Zener dissipation at maximum input and no load0.042350W
Efficiency at minimum input and full load52.381%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 5.1 V Zener, 11-14 V supply, 20 mA load, 5 mA minimum. The inputs, in the units selected above:

InputValue
Minimum input voltage11.000 V
Maximum input voltage14.000 V
Zener voltage5.1000 V
Maximum load current20.000 mA
Minimum Zener current to stay in regulation5.0000 mA

Applying the formula below gives:

ResultValue
Series resistor (largest that still regulates)236.00 Ω
Resistor dissipation at maximum input0.33564 W
Zener current at maximum input and no load37.712 mA
Zener dissipation at maximum input and no load0.19233 W
Efficiency at minimum input and full load37.091 %

Open this example in the calculator and change any input.

Formula

\(R_s = \frac{V_{in,min} - V_Z}{I_L + I_{Z,min}}, \quad I_{Z,max} = \frac{V_{in,max} - V_Z}{R_s}, \quad P_Z = V_ZI_{Z,max}\)

Variables

Symbol Meaning SI unit
\(V_{in,min}\) Minimum input voltage V
\(V_{in,max}\) Maximum input voltage V
\(V_Z\) Zener voltage V
\(I_L\) Maximum load current A
\(I_{Z,min}\) Minimum Zener current to stay in regulation A
\(R_s\) Series resistor (largest that still regulates) Ω
\(P_R\) Resistor dissipation at maximum input W
\(I_{Z,max}\) Zener current at maximum input and no load A
\(P_Z\) Zener dissipation at maximum input and no load W
\(\eta\) Efficiency at minimum input and full load -

Method and standards

Shunt regulator design.

Where it is used

  • Reference voltages and low-current supplies.
  • Over-voltage clamps and bias circuits.

Common mistakes

  • Sizing the Zener for full-load current only.
  • Forgetting the resistor power at maximum input.

Assumptions and limits

  • Ideal Zener (zero dynamic resistance).

References

  • Zener shunt regulator design

Questions and answers

Why is the worst case at no load?

With the load gone, all the current through R_s flows in the Zener; at maximum input that is its highest dissipation.

When should I use a linear regulator instead?

For more than a few tens of milliamperes, or when the input varies widely; a Zener shunt wastes current at all times.

What do the defaults represent?

An illustrative 5.1 V Zener feeding 20 mA from an 11–14 V supply, with at least 5 mA kept in the Zener.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sedra and Smith, Microelectronic Circuits, 7th ed. (Oxford University Press, 2015), ch. 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.