FireCADCalc

VSWR, Return Loss and Mismatch Loss from Load Impedance

Reflection coefficient, VSWR, return loss, mismatch loss and transmitted power fraction of a load on a transmission line from its impedance and the line impedance.

Inputs

Examples: Illustrative: 75 + j20 ohm antenna on a 50 ohm lineResistive 100 ohm on 50 ohmCapacitive load 35 - j15 ohm on 50 ohm

Accepted: 0 to 1,000,000 Ω
Accepted: -1,000,000 to 1,000,000 Ω
Accepted: 1 to 1,000 Ω

Results

Γ = (Z_L − Z₀)/(Z_L + Z₀) for a real line impedance. Return loss and mismatch loss in dB; a VSWR of 2 reflects 11 % of the power (0.5 dB mismatch loss).

Magnitude of the reflection coefficient0.24577
Phase of the reflection coefficient-124.99°
Voltage standing wave ratio1.6517
Return loss (dB)12.189
Mismatch loss (dB)0.27058
Fraction of power delivered93.960%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 75 + j20 ohm antenna on a 50 ohm line. The inputs, in the units selected above:

InputValue
Load resistance75.000 Ω
Load reactance (+ inductive, − capacitive)20.000 Ω
Characteristic impedance of the line50.000 Ω

Applying the formula below gives:

ResultValue
Magnitude of the reflection coefficient0.25291
Phase of the reflection coefficient29.570 °
Voltage standing wave ratio1.6770
Return loss (dB)11.941
Mismatch loss (dB)0.28707
Fraction of power delivered93.604 %

Open this example in the calculator and change any input.

Formula

\(\Gamma = \frac{Z_L - Z_0}{Z_L + Z_0}, \quad VSWR = \frac{1 + |\Gamma|}{1 - |\Gamma|}, \quad RL = -20\log_{10}|\Gamma|, \quad ML = -10\log_{10}(1 - |\Gamma|^2)\)

Variables

Symbol Meaning SI unit
\(R_L\) Load resistance Ω
\(X_L\) Load reactance (+ inductive, − capacitive) Ω
\(Z_0\) Characteristic impedance of the line Ω
\(|\Gamma|\) Magnitude of the reflection coefficient -
\(\angle\Gamma\) Phase of the reflection coefficient rad
\(VSWR\) Voltage standing wave ratio -
\(RL\) Return loss (dB) -
\(ML\) Mismatch loss (dB) -
\(1 - |\Gamma|^2\) Fraction of power delivered -

Method and standards

Transmission line reflection.

Where it is used

  • Antenna and feeder matching, RF amplifier outputs.
  • Cable and connector acceptance tests.

Common mistakes

  • Confusing return loss with mismatch loss.
  • Using the line's length-dependent input impedance as the load.

Assumptions and limits

  • Lossless line with real characteristic impedance.

References

  • Reflection on a terminated transmission line

Questions and answers

What VSWR is acceptable?

Below 1.5 (return loss above 14 dB) is good for most antennas; 2.0 is a common upper limit, losing about 11 % of the power.

Why is return loss positive?

It is defined as the loss of the reflected wave relative to the incident one, −20 log|Γ|; a higher number means a better match.

What do the defaults represent?

An illustrative 75 + j20 Ω antenna on a 50 Ω line.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pozar, Microwave Engineering, 4th ed. (Wiley, 2012), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.