Worked example
Example: Illustrative 1800 K emitter 2.5 eV, 900 K collector 1.7 eV. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Emitter temperature | 1,526.8 °C |
| Emitter work function | 2.5000 eV |
| Collector temperature | 626.85 °C |
| Collector work function | 1.7000 eV |
| Material correction to the Richardson constant (about 0.5) | 0.50000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Emitter current density | 19.482 A/cm² |
| Collector back-emission current density | 0.014712 A/cm² |
| Net current density | 19.467 A/cm² |
| Ideal output voltage (W_e − W_c)/e | 0.80000 V |
| Ideal output power density | 15.574 W/cm² |
Open this example in the calculator and change any input.
Formula
\(J = \lambda_RA_0T^2e^{-W/kT}, \quad A_0 = \frac{4\pi m_eek^2}{h^3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_e\) | Emitter temperature | K |
| \(W_e\) | Emitter work function | J |
| \(T_c\) | Collector temperature | K |
| \(W_c\) | Collector work function | J |
| \(\lambda_R\) | Material correction to the Richardson constant (about 0.5) | - |
| \(J_e\) | Emitter current density | A/m² |
| \(J_c\) | Collector back-emission current density | A/m² |
| \(J\) | Net current density | A/m² |
| \(V\) | Ideal output voltage (W_e − W_c)/e | V |
| \(P/A\) | Ideal output power density | W/m² |
Method and standards
Thermionic emission.
Where it is used
- Space nuclear power and topping cycles.
- Vacuum tube and cathode design.
Common mistakes
- Forgetting the λ_R correction for real surfaces.
- Ignoring space charge.
Assumptions and limits
- Ideal converter; no space charge.
References
- Richardson–Dushman thermionic emission
Questions and answers
Why must the emitter be so hot?
Emission grows as exp(−W/kT); with work functions of 2–3 eV, useful currents need 1,500–2,000 K.
Why a low-work-function collector?
Electrons fall from the emitter's work function to the collector's; the difference is the output voltage, so the collector must emit little itself while having a low work function.
What do the defaults represent?
An illustrative converter with a 1,800 K emitter of 2.5 eV and a 900 K collector of 1.7 eV.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)