Six-Pulse Thyristor Converter: DC Voltage, Overlap and Power Factor

DC output voltage of a three-phase thyristor bridge for a firing angle and load current, with commutation overlap, displacement factor and AC current.

Inputs

Examples: Illustrative 415 V bridge at 30 degreesDC drive at low speed, 70 degreesInverting at 140 degrees

Accepted: 1 to 1,000,000 V
Accepted: 1 to 1,000 Hz
Accepted: 0 to 175 °
Accepted: 0 to 1,000,000 A
Accepted: 0 to 1,000 mH

Results

A six-pulse bridge gives V_d0 = (3√2/π)V_LL ≈ 1.35V_LL; delaying the firing by α scales it by cos α, and above 90° the bridge inverts (negative V_d). The supply inductance makes each commutation last an overlap angle μ, with cos(α + μ) = cos α − 2ωL_cI_d/(√2V_LL), and costs a voltage 3ωL_cI_d/π. The displacement factor is about [cos α + cos(α + μ)]/2 and the fundamental line current (√6/π)I_d for a smooth DC current, so phase-controlled rectifiers draw much reactive power at large α.

Ideal no-load DC voltage at α = 0931.83V
DC output voltage-728.82V
Commutation overlap angle2.9623°
DC power-728.82kW
Displacement factor-0.78214
Fundamental AC line current779.70A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 415 V bridge at 30 degrees. The inputs, in the units selected above:

InputValue
AC line-to-line voltage (RMS)415.00 V
Supply frequency50.000 Hz
Firing (delay) angle30.000 °
DC current200.00 A
Commutating inductance per phase0.10000 mH

Applying the formula below gives:

ResultValue
Ideal no-load DC voltage at α = 0560.45 V
DC output voltage479.36 V
Commutation overlap angle2.3694 °
DC power95.872 kW
Displacement factor0.85532
Fundamental AC line current155.94 A

Open this example in the calculator and change any input.

Formula

\(V_d = \frac{3\sqrt2}{\pi}V_{LL}\cos\alpha - \frac{3\omega L_c}{\pi}I_d, \quad \cos(\alpha + \mu) = \cos\alpha - \frac{2\omega L_cI_d}{\sqrt2V_{LL}}\)

Variables

Symbol Meaning SI unit
\(V_{LL}\) AC line-to-line voltage (RMS) V
\(f\) Supply frequency 1/s
\(\alpha\) Firing (delay) angle rad
\(I_d\) DC current A
\(L_c\) Commutating inductance per phase H
\(V_{d0}\) Ideal no-load DC voltage at α = 0 V
\(V_d\) DC output voltage V
\(\mu\) Commutation overlap angle rad
\(P_d\) DC power W
\(\cos\varphi_1\) Displacement factor -
\(I_1\) Fundamental AC line current A

Method and standards

Thyristor bridge.

Where it is used

  • DC drives, electrolysers and battery chargers.
  • Estimating reactive power of phase-controlled loads.

Common mistakes

  • Using line-to-neutral voltage in 1.35 V_LL.
  • Ignoring overlap at high current.

Assumptions and limits

  • Smooth (continuous) DC current; balanced sinusoidal supply; ideal thyristors.

References

  • Three-phase fully controlled bridge with commutation overlap

Questions and answers

Why does the power factor fall with firing angle?

The fundamental current shifts by about α behind the voltage, so the drive draws reactive power at low speed.

What limits inversion?

The overlap plus the thyristor turn-off margin must fit before 180°, or commutation fails.

What do the defaults represent?

An illustrative 415 V, 50 Hz bridge fired at 30° carrying 200 A with 0.1 mH commutating inductance.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mohan, Undeland and Robbins, Power Electronics: Converters, Applications and Design, 3rd ed. (Wiley, 2003)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.