Worked example
Example: Illustrative X-band radar, 10 m2 target at 20 km. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Peak transmit power | 10.000 kW |
| Antenna gain (dBi) | 30.000 - |
| Frequency | 9.4000 GHz |
| Radar cross-section of the target | 10.000 m² |
| System losses (dB) | 4.0000 - |
| Minimum detectable signal (dBm) | -95.000 - |
| Target range | 20.000 km |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wavelength | 31.893 mm |
| Received power at the range (dBm) | -98.944 |
| Maximum detection range | 15.938 km |
| Margin at the range (dB) | -3.9436 |
Open this example in the calculator and change any input.
Formula
\(P_r = \frac{P_t G^2 \lambda^2 \sigma}{(4\pi)^3 R^4 L}, \quad R_{max} = \left[\frac{P_t G^2 \lambda^2 \sigma}{(4\pi)^3 L\,S_{min}}\right]^{1/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_t\) | Peak transmit power | W |
| \(G\) | Antenna gain (dBi) | - |
| \(f\) | Frequency | 1/s |
| \(\sigma\) | Radar cross-section of the target | m² |
| \(L\) | System losses (dB) | - |
| \(S_{min}\) | Minimum detectable signal (dBm) | - |
| \(R\) | Target range | m |
| \(\lambda\) | Wavelength | m |
| \(P_r\) | Received power at the range (dBm) | - |
| \(R_{max}\) | Maximum detection range | m |
| \(P_r - S_{min}\) | Margin at the range (dB) | - |
Method and standards
Radar equation.
Where it is used
- Radar level gauges, traffic and marine radars.
- Teaching RF link budgets.
Common mistakes
- Using one-way free-space loss.
- Mixing dBm and watts.
Assumptions and limits
- Free space; same antenna for transmit and receive; no clutter.
References
- Monostatic radar range equation
Questions and answers
Why does radar range grow only with the fourth root of power?
The echo travels out and back, so power falls as R⁴.
What cross-section does a car have?
Roughly 10–100 m² at microwave frequencies, depending strongly on angle.
What do the defaults represent?
An illustrative X-band (9.4 GHz) radar with 10 kW, 30 dBi antenna and −95 dBm sensitivity against a 10 m² target at 20 km.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Skolnik, Introduction to Radar Systems, 3rd ed. (McGraw-Hill, 2001)