FireCADCalc

Quarter-Wave Transformer: Impedance, Length and Bandwidth

Line impedance and physical length of a quarter-wave matching section between two resistances, and its fractional bandwidth for a maximum VSWR.

Inputs

Examples: Illustrative 50 to 100 ohm at 2.4 GHz50 to 25 ohm, tight VSWR75 to 300 ohm antenna

Accepted: 1 to 1,000 Ω
Accepted: 1 to 1,000 Ω
Accepted: 1E-6 to 100 GHz
Accepted: 30 to 100 %
Accepted: 1.01 to 5

Results

A line a quarter wavelength long transforms a load Z_L into Z_T²/Z_L, so Z_T = √(Z₀Z_L) matches it. The physical length is a quarter of the free-space wavelength times the line's velocity factor. The match is exact only at the design frequency; the band over which the VSWR stays below S_max is Δf/f₀ = 2 − (4/π) arccos[Γ_m/√(1 − Γ_m²) · 2√(Z₀Z_L)/|Z_L − Z₀|] (TEM line). Larger impedance ratios give narrower bands; cascade several sections for wider ones.

Impedance of the quarter-wave section70.711Ω
Physical length20.611mm
Reflection coefficient at the VSWR limit0.20000
Fractional bandwidth for that VSWR78.365%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 to 100 ohm at 2.4 GHz. The inputs, in the units selected above:

InputValue
Feed line impedance50.000 Ω
Load resistance100.00 Ω
Design frequency2.4000 GHz
Velocity factor of the line66.000 %
Highest acceptable VSWR1.5000 -

Applying the formula below gives:

ResultValue
Impedance of the quarter-wave section70.711 Ω
Physical length20.611 mm
Reflection coefficient at the VSWR limit0.20000
Fractional bandwidth for that VSWR78.365 %

Open this example in the calculator and change any input.

Formula

\(Z_T = \sqrt{Z_0 Z_L}, \quad \ell = \frac{v_f c}{4f_0}, \quad \frac{\Delta f}{f_0} = 2 - \frac4\pi\arccos\left[\frac{\Gamma_m}{\sqrt{1-\Gamma_m^2}}\frac{2\sqrt{Z_0Z_L}}{|Z_L - Z_0|}\right]\)

Variables

Symbol Meaning SI unit
\(Z_0\) Feed line impedance Ω
\(Z_L\) Load resistance Ω
\(f_0\) Design frequency 1/s
\(v_f\) Velocity factor of the line -
\(S_{max}\) Highest acceptable VSWR -
\(Z_T\) Impedance of the quarter-wave section Ω
\(\ell\) Physical length m
\(\Gamma_m\) Reflection coefficient at the VSWR limit -
\(\Delta f/f_0\) Fractional bandwidth for that VSWR -

Method and standards

Quarter-wave transformer.

Where it is used

  • Antenna feeds and power dividers.
  • Matching on printed circuit boards.

Common mistakes

  • Using the free-space wavelength for a cable.
  • Matching complex loads without first making them real.

Assumptions and limits

  • Lossless TEM line; resistive load.

References

  • Quarter-wave transformer and its bandwidth

Questions and answers

What impedance matches 50 Ω to 100 Ω?

A quarter-wave section of 70.7 Ω.

Why is my match narrow-band?

A single section matches exactly only at one frequency; the band shrinks as the impedance ratio grows.

What do the defaults represent?

An illustrative 2.4 GHz match from 50 Ω to 100 Ω on a line with velocity factor 0.66, for VSWR 1.5.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pozar, Microwave Engineering, 4th ed. (Wiley, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.