FireCADCalc

Cascaded Noise Figure of a Receiver Chain (Friis)

Overall noise figure, noise temperature and gain of up to three cascaded stages, such as an LNA, cable and mixer, by Friis's formula for noise.

Inputs

Examples: Illustrative: LNA 1 dB / 18 dB, 3 dB cable, mixer 10 dB / 20 dBCable first: 3 dB loss before the LNASatellite LNB: 0.5 dB / 30 dB, then 8 dB / 10 dB, then 12 dB / 20 dB

Accepted: 0 to 40
Accepted: -60 to 60
Accepted: 0 to 40
Accepted: -60 to 60
Accepted: 0 to 40
Accepted: -60 to 60

Results

Friis: F = F₁ + (F₂ − 1)/G₁ + (F₃ − 1)/(G₁G₂), with linear factors; T_e = 290(F − 1) K. A high-gain, low-noise first stage makes the later stages almost irrelevant.

Overall noise factor (linear)1.1288
Overall noise figure (dB)0.52622
Equivalent noise temperature37.356K
Overall gain (dB)60.000
Noise figure added after stage 1 (dB)0.026220

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: LNA 1 dB / 18 dB, 3 dB cable, mixer 10 dB / 20 dB. The inputs, in the units selected above:

InputValue
Stage 1 noise figure (dB)1.0000 -
Stage 1 gain (dB; loss negative)18.000 -
Stage 2 noise figure (dB; a passive loss L has NF = L)3.0000 -
Stage 2 gain (dB)-3.0000 -
Stage 3 noise figure (dB)10.000 -
Stage 3 gain (dB)20.000 -

Applying the formula below gives:

ResultValue
Overall noise factor (linear)1.5593
Overall noise figure (dB)1.9293
Equivalent noise temperature162.20 K
Overall gain (dB)35.000
Noise figure added after stage 1 (dB)0.92931

Open this example in the calculator and change any input.

Formula

\(F = F_1 + \frac{F_2 - 1}{G_1} + \frac{F_3 - 1}{G_1G_2}, \quad NF = 10\log_{10}F, \quad T_e = 290(F - 1)\)

Variables

Symbol Meaning SI unit
\(NF_1\) Stage 1 noise figure (dB) -
\(G_1\) Stage 1 gain (dB; loss negative) -
\(NF_2\) Stage 2 noise figure (dB; a passive loss L has NF = L) -
\(G_2\) Stage 2 gain (dB) -
\(NF_3\) Stage 3 noise figure (dB) -
\(G_3\) Stage 3 gain (dB) -
\(F\) Overall noise factor (linear) -
\(NF\) Overall noise figure (dB) -
\(T_e\) Equivalent noise temperature K
\(G\) Overall gain (dB) -
\(\Delta NF_{1}\) Noise figure added after stage 1 (dB) -

Method and standards

Friis noise cascade.

Where it is used

  • Receiver front-end design, satellite and radio astronomy systems.
  • Placement of LNAs and feeder losses.

Common mistakes

  • Adding noise figures in dB.
  • Forgetting that a lossy stage has gain below 1.

Assumptions and limits

  • Matched stages, linear operation, standard 290 K reference.

References

  • Friis formula for cascaded noise

Questions and answers

Why put the LNA at the antenna?

Any loss before the first amplifier adds directly to the noise figure; after a high-gain LNA the cable loss barely matters.

What is the noise figure of a cable?

A passive loss of L dB at room temperature has a noise figure of L dB and a gain of −L dB.

What do the defaults represent?

An illustrative chain: an 18 dB LNA with 1 dB noise figure, 3 dB of cable, then a mixer with 10 dB noise figure and 20 dB gain.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pozar, Microwave Engineering, 4th ed. (Wiley, 2012), ch. 10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.