Worked example
Example: Illustrative: 5 V from 12 V at 0.5 A, R1 240 ohm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Required output voltage | 5.0000 V |
| Resistor from output to adjust (typically 240 Ω) | 240.00 Ω |
| Reference voltage | 1.2500 V |
| Adjust-pin current | 0.050000 mA |
| Input voltage | 12.000 V |
| Load current | 0.50000 A |
| Dropout voltage | 2.5000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Resistor from adjust to ground | 713.15 Ω |
| R₂ ignoring the adjust current | 720.00 Ω |
| Minimum input voltage V_out + V_do | 7.5000 V |
| Regulator dissipation (V_in − V_out) I_out | 3.5000 W |
| Efficiency V_out/V_in | 41.667 % |
Open this example in the calculator and change any input.
Formula
\(V_{out} = V_{ref}\left(1 + \frac{R_2}{R_1}\right) + I_{adj}R_2 \;\Rightarrow\; R_2 = \frac{V_{out} - V_{ref}}{V_{ref}/R_1 + I_{adj}}, \quad P_D = (V_{in} - V_{out})I_{out}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_{out}\) | Required output voltage | V |
| \(R_1\) | Resistor from output to adjust (typically 240 Ω) | Ω |
| \(V_{ref}\) | Reference voltage | V |
| \(I_{adj}\) | Adjust-pin current | A |
| \(V_{in}\) | Input voltage | V |
| \(I_{out}\) | Load current | A |
| \(V_{do}\) | Dropout voltage | V |
| \(R_2\) | Resistor from adjust to ground | Ω |
| \(R_{2,ideal}\) | R₂ ignoring the adjust current | Ω |
| \(V_{in,min}\) | Minimum input voltage V_out + V_do | V |
| \(P_D\) | Regulator dissipation (V_in − V_out) I_out | W |
| \(\eta\) | Efficiency V_out/V_in | - |
Method and standards
Adjustable linear regulator design.
Where it is used
- Bench and laboratory supplies, sensor supplies.
- Post-regulation after switching converters.
Common mistakes
- Forgetting the dropout voltage.
- Ignoring the heat dissipated in the regulator.
Assumptions and limits
- Typical datasheet values for V_ref, I_adj and dropout.
References
- Adjustable three-terminal regulator relations
Questions and answers
Why is R₁ usually 240 Ω?
1.25 V across 240 Ω draws about 5 mA, enough to meet the regulator's minimum load current with no load connected.
When is a linear regulator a poor choice?
When V_in − V_out times the current is large: 7 V dropped at 0.5 A wastes 3.5 W as heat, and a switching regulator would be better.
What do the defaults represent?
An illustrative 5 V output from 12 V at 0.5 A with R₁ = 240 Ω.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 9