FireCADCalc

L-Network Impedance Matching (Resistive Source and Load)

Loaded Q, series and shunt reactances and component values of a low-pass L network that matches a resistive source to a resistive load at a frequency.

Inputs

Examples: Illustrative 50 to 10 ohm at 14 MHzTransducer 1000 to 50 ohm at 40 kHzPA output 5 to 50 ohm at 900 MHz

Accepted: 0.01 to 1,000,000 Ω
Accepted: 0.01 to 1,000,000 Ω
Accepted: 1E-6 to 100,000 MHz

Results

An L network has one series and one shunt element; the shunt element goes across the higher resistance. Its Q is fixed by the resistance ratio, Q = √(R_high/R_low − 1), giving X_s = Q R_low and X_p = R_high/Q. The low-pass form (series inductor, shunt capacitor) also filters harmonics. For a wider or narrower bandwidth than f/Q allows, use a pi or T network; for complex loads, absorb the load reactance into the elements.

Loaded Q of the network4.3589
Series reactance (inductor)217.94Ω
Shunt reactance (capacitor, on the higher-resistance side)229.42Ω
Series inductance867.18µH
Shunt capacitance17,344pF
Approximate 3 dB bandwidth f/Q0.009177MHz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 50 to 10 ohm at 14 MHz. The inputs, in the units selected above:

InputValue
Source resistance50.000 Ω
Load resistance10.000 Ω
Frequency14.000 MHz

Applying the formula below gives:

ResultValue
Loaded Q of the network2.0000
Series reactance (inductor)20.000 Ω
Shunt reactance (capacitor, on the higher-resistance side)25.000 Ω
Series inductance0.22736 µH
Shunt capacitance454.73 pF
Approximate 3 dB bandwidth f/Q7.0000 MHz

Open this example in the calculator and change any input.

Formula

\(Q = \sqrt{\frac{R_{high}}{R_{low}} - 1}, \quad X_s = QR_{low}, \quad X_p = \frac{R_{high}}{Q}\)

Variables

Symbol Meaning SI unit
\(R_s\) Source resistance Ω
\(R_L\) Load resistance Ω
\(f\) Frequency 1/s
\(Q\) Loaded Q of the network -
\(X_s\) Series reactance (inductor) Ω
\(X_p\) Shunt reactance (capacitor, on the higher-resistance side) Ω
\(L\) Series inductance H
\(C\) Shunt capacitance F
\(BW\) Approximate 3 dB bandwidth f/Q 1/s

Method and standards

L network.

Where it is used

  • RF amplifier and antenna matching.
  • Ultrasonic and induction transducer matching.

Common mistakes

  • Putting the shunt element on the low-resistance side.
  • Ignoring component losses at high Q.

Assumptions and limits

  • Resistive source and load; ideal components.

References

  • L-network matching of resistive impedances

Questions and answers

Where does the shunt element go?

Across the higher resistance.

Can I choose the Q?

Not with an L network: it is set by the resistance ratio; use a pi or T network for a chosen Q.

What do the defaults represent?

An illustrative 50 Ω source matched to a 10 Ω load at 14 MHz.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bowick, RF Circuit Design, 2nd ed. (Newnes, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.