Worked example
Example: Illustrative 100 A IGBT at 8 kHz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| On-state threshold voltage | 0.90000 V |
| On-state slope resistance | 12.000 mΩ |
| Average current in the switch | 35.000 A |
| RMS current in the switch | 55.000 A |
| Turn-on energy at the datasheet point | 3.5000 mJ |
| Turn-off energy at the datasheet point | 2.8000 mJ |
| Datasheet test voltage | 600.00 V |
| Datasheet test current | 100.00 A |
| DC link voltage | 560.00 V |
| Average current switched | 50.000 A |
| Switching frequency | 8.0000 kHz |
| Junction-to-case thermal resistance (K/W) | 0.25000 - |
| Case-to-ambient (interface and heat sink) thermal resistance (K/W) | 0.35000 - |
| Ambient temperature | 40.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Conduction loss | 67.800 W |
| Switching loss | 23.520 W |
| Total loss | 91.320 W |
| Case temperature | 71.962 °C |
| Junction temperature | 94.792 °C |
Open this example in the calculator and change any input.
Formula
\(P_{cond} = V_{CE0}I_{av} + r_{CE}I_{rms}^2, \quad P_{sw} = (E_{on} + E_{off}) f_s \frac{V_{dc}}{V_{ref}}\frac{I_{sw}}{I_{ref}}, \quad T_j = T_a + P(R_{\theta JC} + R_{\theta CA})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_{CE0}\) | On-state threshold voltage | V |
| \(r_{CE}\) | On-state slope resistance | Ω |
| \(I_{av}\) | Average current in the switch | A |
| \(I_{rms}\) | RMS current in the switch | A |
| \(E_{on}\) | Turn-on energy at the datasheet point | J |
| \(E_{off}\) | Turn-off energy at the datasheet point | J |
| \(V_{ref}\) | Datasheet test voltage | V |
| \(I_{ref}\) | Datasheet test current | A |
| \(V_{dc}\) | DC link voltage | V |
| \(I_{sw}\) | Average current switched | A |
| \(f_s\) | Switching frequency | 1/s |
| \(R_{\theta JC}\) | Junction-to-case thermal resistance (K/W) | - |
| \(R_{\theta CA}\) | Case-to-ambient (interface and heat sink) thermal resistance (K/W) | - |
| \(T_a\) | Ambient temperature | K |
| \(P_{cond}\) | Conduction loss | W |
| \(P_{sw}\) | Switching loss | W |
| \(P\) | Total loss | W |
| \(T_c\) | Case temperature | K |
| \(T_j\) | Junction temperature | K |
Method and standards
IGBT losses.
Where it is used
- Inverter and drive thermal design.
- Choosing switching frequency and heat sinks.
Common mistakes
- Using switching energies at 25 °C.
- Forgetting the diode losses in the same module.
Assumptions and limits
- Linear scaling; steady-state temperatures.
References
- Piecewise-linear on-state model and linear scaling of switching energies
Questions and answers
How do I scale the datasheet switching energy?
Linearly with voltage and current: E = E_ref (V/V_ref)(I/I_ref), at the same gate resistance and temperature.
Why use RMS current for the resistive part?
The loss in a resistance depends on the square of the current, averaged over time.
What do the defaults represent?
An illustrative 100 A, 1200 V IGBT in an inverter on a 560 V link at 8 kHz, 40 °C ambient.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Mohan, Undeland and Robbins, Power Electronics, 3rd ed. (Wiley, 2003)