Worked example
Example: Illustrative: 15 W, R_JC 1.5, interface 0.5 K/W, 125 C limit, 50 C air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Power dissipated | 15.000 W |
| Maximum junction temperature (with margin) | 125.00 °C |
| Ambient (air inside the enclosure) | 50.000 °C |
| Junction-to-case thermal resistance (K/W) | 1.5000 - |
| Case-to-sink (interface) thermal resistance (K/W) | 0.50000 - |
| Junction-to-ambient without a heat sink (K/W) | 62.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Required heat sink to air resistance (K/W) | 3.0000 |
| Case temperature at the limit | 102.50 °C |
| Heat sink temperature at the limit | 95.000 °C |
| Junction temperature with no heat sink | 980.00 °C |
| Maximum power with no heat sink | 1.2097 W |
Open this example in the calculator and change any input.
Formula
\(R_{\theta SA} = \frac{T_{j,max} - T_a}{P} - R_{\theta JC} - R_{\theta CS}, \quad T_j = T_a + P(R_{\theta JC} + R_{\theta CS} + R_{\theta SA})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Power dissipated | W |
| \(T_{j,max}\) | Maximum junction temperature (with margin) | K |
| \(T_a\) | Ambient (air inside the enclosure) | K |
| \(R_{θJC}\) | Junction-to-case thermal resistance (K/W) | - |
| \(R_{θCS}\) | Case-to-sink (interface) thermal resistance (K/W) | - |
| \(R_{θJA}\) | Junction-to-ambient without a heat sink (K/W) | - |
| \(R_{θSA}\) | Required heat sink to air resistance (K/W) | - |
| \(T_c\) | Case temperature at the limit | K |
| \(T_s\) | Heat sink temperature at the limit | K |
| \(T_{j,bare}\) | Junction temperature with no heat sink | K |
| \(P_{max,bare}\) | Maximum power with no heat sink | W |
Method and standards
Thermal resistance network.
Where it is used
- Regulators, MOSFETs, IGBTs and LED modules.
- Enclosure and fan selection.
Common mistakes
- Using the room temperature instead of the air inside the enclosure.
- Ignoring the interface resistance.
Assumptions and limits
- Steady state, one-dimensional series heat path.
References
- Series thermal resistance network for semiconductors
Questions and answers
Why use 125 °C instead of the 150 °C rating?
Reliability falls quickly with temperature; designing for 100–125 °C leaves margin for hot spots, tolerances and ageing.
How much does thermal paste help?
A dry metal joint may be 1–2 K/W; a good grease or pad brings it to 0.1–0.5 K/W, often the difference between a small and a large heat sink.
What do the defaults represent?
An illustrative 15 W device with R_θJC 1.5 K/W and a 0.5 K/W interface, kept below 125 °C in 50 °C enclosure air.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 9