FireCADCalc

Gapped Inductor Design: Turns and Air Gap

Turns and air gap of a gapped ferrite inductor for an inductance and peak current without exceeding a flux density, from the core area and magnetic path.

Inputs

Examples: Illustrative 100 uH, 5 AFlyback primary 400 uH, 1.5 APFC choke 1 mH, 8 A

Accepted: 0.001 to 10,000,000 µH
Accepted: 0.001 to 10,000 A
Accepted: 0.1 to 10,000 mm²
Accepted: 1 to 2,000 mm
Accepted: 1 to 100,000
Accepted: 0.01 to 2 T

Results

Faraday's law fixes the turns: N = L I_pk/(B_max A_e) keeps the peak flux density at B_max. The gap then sets the inductance with those turns: L = μ₀N²A_e/(l_g + l_e/μ_r), so l_g = μ₀N²A_e/L − l_e/μ_r. Almost all the energy is stored in the gap. Fringing near a large gap raises the inductance a few per cent and heats nearby windings; check the window area for the wire and the core loss at the ripple current.

Turns (before rounding)13.889
Turns, rounded up14.000
Total air gap for the rounded turns0.26056mm
Peak flux density with the rounded turns0.29762T
Energy stored at peak current1.2500mJ
Inductance factor of the gapped core510.20nH

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 uH, 5 A. The inputs, in the units selected above:

InputValue
Inductance wanted100.00 µH
Peak current5.0000 A
Effective core area120.00 mm²
Effective magnetic path length70.000 mm
Relative permeability of the core material2,000.0 -
Highest flux density allowed0.30000 T

Applying the formula below gives:

ResultValue
Turns (before rounding)13.889
Turns, rounded up14.000
Total air gap for the rounded turns0.26056 mm
Peak flux density with the rounded turns0.29762 T
Energy stored at peak current1.2500 mJ
Inductance factor of the gapped core510.20 nH

Open this example in the calculator and change any input.

Formula

\(N = \frac{L I_{pk}}{B_{max}A_e}, \quad l_g = \frac{\mu_0 N^2 A_e}{L} - \frac{l_e}{\mu_r}, \quad E = \frac12 L I_{pk}^2\)

Variables

Symbol Meaning SI unit
\(L\) Inductance wanted H
\(I_{pk}\) Peak current A
\(A_e\) Effective core area m²
\(l_e\) Effective magnetic path length m
\(\mu_r\) Relative permeability of the core material -
\(B_{max}\) Highest flux density allowed T
\(N\) Turns (before rounding) -
\(N_{sel}\) Turns, rounded up -
\(l_g\) Total air gap for the rounded turns m
\(B_{pk}\) Peak flux density with the rounded turns T
\(E\) Energy stored at peak current J
\(A_L\) Inductance factor of the gapped core H

Method and standards

Gapped inductor.

Where it is used

  • Buck, boost and flyback magnetics.
  • PFC chokes.

Common mistakes

  • Splitting the gap between two legs without halving it per leg.
  • Designing for B_max at the average instead of the peak current.

Assumptions and limits

  • No fringing; uniform flux; linear core.

References

  • Gapped-core inductor design from Faraday's law and the magnetic circuit

Questions and answers

Why does an inductor need a gap?

Ferrite saturates at about 0.3–0.4 T; the gap stores the energy and keeps the flux below saturation at the peak current.

Why round the turns up?

Fewer turns would raise the flux density above the limit; the gap is then recalculated for the rounded turns.

What do the defaults represent?

An illustrative 100 µH, 5 A inductor on a core with 120 mm² area and 70 mm path, μ_r = 2000, B_max 0.3 T.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

McLyman, Transformer and Inductor Design Handbook, 4th ed. (CRC Press, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.