FireCADCalc

Flyback Converter: Duty Cycle, Primary Inductance and Stresses

Duty cycle, critical primary inductance, peak primary current and switch voltage of a flyback converter at the boundary of continuous conduction.

Inputs

Examples: Illustrative 36 W off-line flyback24 V input, 5 V outputAuxiliary 15 V supply

Accepted: 1 to 2,000 V
Accepted: 1 to 2,000 V
Accepted: 1 to 1,000 V
Accepted: 0 to 5 V
Accepted: 0.05 to 100
Accepted: 0.0001 to 10 kW
Accepted: 1 to 5,000 kHz
Accepted: 50 to 100 %

Results

The output voltage reflected to the primary, V_R = n(V_o + V_F), and volt-second balance give the duty cycle D = V_R/(V_in + V_R). At the boundary between continuous and discontinuous conduction the primary current ramps from zero to I_pk = 2P_in/(V_in D) each cycle, which needs L_p = V_in D/(I_pk f_s), equivalent to L_p = (V_in D)²/(2P_in f_s). A larger inductance runs continuous (lower peak current); a smaller one discontinuous. The switch sees V_in + V_R plus a leakage-inductance spike that the clamp must absorb.

Duty cycle at the lowest input50.000%
Primary inductance for boundary conduction at full load295.14µH
Peak primary current1.6941A
Switch voltage at the highest input (before leakage spike)475.00V
Reflected output voltage100.00V

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 36 W off-line flyback. The inputs, in the units selected above:

InputValue
Lowest input voltage100.00 V
Highest input voltage375.00 V
Output voltage12.000 V
Output diode forward drop0.50000 V
Turns ratio N_p/N_s8.0000 -
Output power0.036000 kW
Switching frequency100.00 kHz
Efficiency85.000 %

Applying the formula below gives:

ResultValue
Duty cycle at the lowest input50.000 %
Primary inductance for boundary conduction at full load295.14 µH
Peak primary current1.6941 A
Switch voltage at the highest input (before leakage spike)475.00 V
Reflected output voltage100.00 V

Open this example in the calculator and change any input.

Formula

\(V_R = n(V_o + V_F), \quad D = \frac{V_R}{V_{in} + V_R}, \quad I_{pk} = \frac{2P_{in}}{V_{in}D}, \quad L_p = \frac{V_{in}D}{I_{pk}f_s}\)

Variables

Symbol Meaning SI unit
\(V_{in,min}\) Lowest input voltage V
\(V_{in,max}\) Highest input voltage V
\(V_o\) Output voltage V
\(V_F\) Output diode forward drop V
\(n\) Turns ratio N_p/N_s -
\(P_o\) Output power W
\(f_s\) Switching frequency 1/s
\(\eta\) Efficiency -
\(D\) Duty cycle at the lowest input -
\(L_p\) Primary inductance for boundary conduction at full load H
\(I_{pk}\) Peak primary current A
\(V_{DS}\) Switch voltage at the highest input (before leakage spike) V
\(V_R\) Reflected output voltage V

Method and standards

Flyback converter.

Where it is used

  • Off-line chargers and auxiliary supplies.
  • Isolated low-power supplies.

Common mistakes

  • Forgetting the diode drop in the reflected voltage.
  • Ignoring the leakage spike on the switch.

Assumptions and limits

  • Boundary conduction at the lowest input and full load; ideal transformer.

References

  • Flyback converter at the conduction boundary

Questions and answers

How do I choose the turns ratio?

So that V_in,max + V_R plus about 30 % spike margin stays below the MOSFET rating, and D at minimum input stays below about 0.5.

Why is the transformer gapped?

A flyback stores energy in the core each cycle; the gap holds the energy without saturating it.

What do the defaults represent?

An illustrative 36 W, 12 V off-line flyback with 100–375 V DC input, 8:1 turns at 100 kHz.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mohan, Undeland and Robbins, Power Electronics, 3rd ed. (Wiley, 2003)

Related calculators