FireCADCalc

Buck Converter Duty Cycle, Inductor and Output Capacitor

Duty cycle, inductance for a chosen ripple, peak current, output capacitance for a ripple voltage and the continuous-conduction limit of a buck converter.

Inputs

Examples: Illustrative: 12 V to 3.3 V, 3 A, 500 kHz, 30 % ripple, 20 mV24 V to 5 V, 2 A, 200 kHz, 40 % ripple, 50 mV48 V to 12 V, 10 A, 100 kHz, 25 % ripple, 100 mV

Accepted: 1 to 1,000 V
Accepted: 0.3 to 1,000 V
Accepted: 0.001 to 1,000 A
Accepted: 1 to 100,000 kHz
Accepted: 5 to 200 %
Accepted: 0.1 to 10,000 mV
Accepted: 50 to 100 %

Results

Continuous conduction: L = (V_in − V_out)D/(f ΔI), C ≥ ΔI/(8fΔV). Capacitor ESR adds ESR·ΔI to the ripple and often dominates with electrolytics; check L at the maximum input voltage, where ripple is largest.

Duty cycle22.645%
Inductance26.891µH
Inductor ripple current (peak to peak)0.80000A
Peak inductor and switch current2.4000A
Minimum output capacitance (ignoring ESR)10.000µF
Load below which conduction becomes discontinuous0.40000A
Average input current0.45290A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 12 V to 3.3 V, 3 A, 500 kHz, 30 % ripple, 20 mV. The inputs, in the units selected above:

InputValue
Input voltage12.000 V
Output voltage3.3000 V
Output current3.0000 A
Switching frequency500.00 kHz
Inductor ripple ratio ΔI/I_out30.000 %
Allowed output ripple (peak to peak)20.000 mV
Estimated efficiency90.000 %

Applying the formula below gives:

ResultValue
Duty cycle30.556 %
Inductance5.9074 µH
Inductor ripple current (peak to peak)0.90000 A
Peak inductor and switch current3.4500 A
Minimum output capacitance (ignoring ESR)11.250 µF
Load below which conduction becomes discontinuous0.45000 A
Average input current0.91667 A

Open this example in the calculator and change any input.

Formula

\(D = \frac{V_{out}}{\eta V_{in}}, \quad L = \frac{(V_{in} - V_{out})D}{f_s\,\Delta I_L}, \quad C_{out} = \frac{\Delta I_L}{8f_s\Delta V_{out}}, \quad I_{pk} = I_{out} + \frac{\Delta I_L}{2}\)

Variables

Symbol Meaning SI unit
\(V_{in}\) Input voltage V
\(V_{out}\) Output voltage V
\(I_{out}\) Output current A
\(f_s\) Switching frequency 1/s
\(r\) Inductor ripple ratio ΔI/I_out -
\(\Delta V_{out}\) Allowed output ripple (peak to peak) V
\(\eta\) Estimated efficiency -
\(D\) Duty cycle -
\(L\) Inductance H
\(\Delta I_L\) Inductor ripple current (peak to peak) A
\(I_{pk}\) Peak inductor and switch current A
\(C_{out}\) Minimum output capacitance (ignoring ESR) F
\(I_{CCM}\) Load below which conduction becomes discontinuous A
\(I_{in}\) Average input current A

Method and standards

Buck converter steady-state analysis.

Where it is used

  • Point-of-load supplies, battery-powered devices.
  • Selecting inductors and capacitors from catalogues.

Common mistakes

  • Choosing an inductor saturating below the peak current.
  • Ignoring ESR in the output ripple.

Assumptions and limits

  • Continuous conduction, steady state, ideal components except the efficiency.

References

  • Steady-state buck converter relations (volt-second and charge balance)

Questions and answers

What ripple ratio should I choose?

About 20–40 % of the output current: smaller ripple needs a large inductor, larger ripple raises peak current and output ripple.

Why does ESR matter so much?

The ripple current flows through the capacitor's series resistance; 30 mΩ with 0.9 A ripple already gives 27 mV, more than the capacitive part.

What do the defaults represent?

An illustrative 12 V to 3.3 V, 3 A buck at 500 kHz with 30 % ripple current and 20 mV output ripple.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Erickson and Maksimović, Fundamentals of Power Electronics, 2nd ed. (Kluwer, 2001), ch. 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.