FireCADCalc

Thévenin and Norton Equivalent from Open- and Short-Circuit Tests

Thévenin voltage and resistance and Norton current of a source from its open-circuit voltage and short-circuit current, with the load current and power.

Inputs

Examples: Illustrative 12 V source and 6 ohm loadBattery under heavy loadSensor into a high-impedance input

Accepted: 1E-6 to 1,000,000 V
Accepted: 1E-9 to 1,000,000 A
Accepted: 0 to 1E+9 Ω

Results

Any linear two-terminal network behaves as a voltage source V_th = V_oc in series with R_th, or a current source I_N = I_sc in parallel with the same resistance, R_th = V_oc/I_sc. The load then draws V_oc/(R_th + R_L). Maximum power reaches a load equal to R_th, but only at 50 % efficiency; power systems run at loads far above R_th for efficiency. Measure I_sc only where a short circuit is safe, or find R_th with the sources set to zero.

Thévenin (and Norton) resistance0.021000Ω
Load current177.46A
Load voltage8.8732V
Load power1,574.7W
Maximum power (at R_L = R_th)1,890.0W
Share of source power reaching the load70.423%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 12 V source and 6 ohm load. The inputs, in the units selected above:

InputValue
Open-circuit voltage12.000 V
Short-circuit current3.0000 A
Load resistance6.0000 Ω

Applying the formula below gives:

ResultValue
Thévenin (and Norton) resistance4.0000 Ω
Load current1.2000 A
Load voltage7.2000 V
Load power8.6400 W
Maximum power (at R_L = R_th)9.0000 W
Share of source power reaching the load60.000 %

Open this example in the calculator and change any input.

Formula

\(R_{th} = \frac{V_{oc}}{I_{sc}}, \quad I_L = \frac{V_{oc}}{R_{th} + R_L}, \quad P_{max} = \frac{V_{oc}^2}{4R_{th}}\)

Variables

Symbol Meaning SI unit
\(V_{oc}\) Open-circuit voltage V
\(I_{sc}\) Short-circuit current A
\(R_L\) Load resistance Ω
\(R_{th}\) Thévenin (and Norton) resistance Ω
\(I_L\) Load current A
\(V_L\) Load voltage V
\(P_L\) Load power W
\(P_{max}\) Maximum power (at R_L = R_th) W
\(\eta\) Share of source power reaching the load -

Method and standards

Thévenin.

Where it is used

  • Circuit analysis and battery or sensor modelling.
  • Electrical examinations.

Common mistakes

  • Shorting sources that cannot stand it.
  • Applying to non-linear sources.

Assumptions and limits

  • Linear network; DC or a single frequency.

References

  • Thévenin and Norton theorems

Questions and answers

What is the Thévenin resistance of a source with 12 V open circuit and 3 A short circuit?

4 Ω; a 6 Ω load draws 1.2 A and takes 8.64 W.

When is power transfer greatest?

When the load equals R_th, here 9 W at 4 Ω.

What do the defaults represent?

A source with 12 V open-circuit voltage and 3 A short-circuit current, feeding a 6 Ω load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.