Worked example
Example: Illustrative 10 and 4 mH, k = 0.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inductance 1 | 10.000 mH |
| Inductance 2 | 4.0000 mH |
| Coupling coefficient | 0.60000 - |
| Current (series connection) | 2.0000 A |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mutual inductance | 3.7947 mH |
| Series aiding | 21.589 mH |
| Series opposing | 6.4105 mH |
| Parallel aiding | 3.9934 mH |
| Energy stored, series aiding | 0.043179 J |
Open this example in the calculator and change any input.
Formula
\(M = k\sqrt{L_1L_2}, \quad L_{s\pm} = L_1 + L_2 \pm 2M, \quad L_{p+} = \frac{L_1L_2 - M^2}{L_1 + L_2 - 2M}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Inductance 1 | H |
| \(L_2\) | Inductance 2 | H |
| \(k\) | Coupling coefficient | - |
| \(I\) | Current (series connection) | A |
| \(M\) | Mutual inductance | H |
| \(L_{s+}\) | Series aiding | H |
| \(L_{s-}\) | Series opposing | H |
| \(L_{p+}\) | Parallel aiding | H |
| \(W\) | Energy stored, series aiding | J |
Method and standards
Coupled inductors.
Where it is used
- Inductor and transformer design checks.
- Teaching and lab measurements.
Common mistakes
- Forgetting the dot convention (aiding versus opposing).
- Using k above 1.
Assumptions and limits
- Linear inductors; no losses.
References
- Coupled inductor relations
Questions and answers
How is mutual inductance measured?
Measure the series inductance both ways round: M is a quarter of the difference.
What coupling do transformers have?
Close to 1 for iron-cored power transformers; air-cored coils are often 0.1–0.5.
What do the defaults represent?
Illustrative 10 mH and 4 mH coils with coupling 0.6 carrying 2 A in series.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Hayt, Kemmerly and Durbin, Engineering Circuit Analysis, 8th ed. (McGraw-Hill, 2012)