Worked example
Example: Illustrative: 500 turns, 2 A, 30 x 30 mm core, 400 mm path, mu_r 3000, 1 mm gap with fringing. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of turns | 500.00 - |
| Coil current | 2.0000 A |
| Mean magnetic path length in the core | 400.00 mm |
| Core cross-section area | 9.0000 cm² |
| Relative permeability of the core | 3,000.0 - |
| Air gap length (0 for none) | 1.0000 mm |
| Gap fringing | Add the gap length to each side of a square pole |
Applying the formula below gives:
| Result | Value |
|---|---|
| Magnetomotive force NI | 1,000.0 A |
| Core reluctance | 117,893 A/Wb |
| Gap reluctance | 828,069 A/Wb |
| Flux | 1.0571 mWb |
| Flux density in the core | 1.1746 T |
| Field strength in the core | 311.57 A/m |
| Inductance N²/ℛ | 264.28 mH |
| Stored energy ½LI² | 0.52856 J |
Open this example in the calculator and change any input.
Formula
\(\mathcal{R}_c = \frac{l_c}{\mu_0\mu_r A_c}, \quad \mathcal{R}_g = \frac{l_g}{\mu_0 A_g}, \quad \Phi = \frac{NI}{\mathcal{R}_c + \mathcal{R}_g}, \quad L = \frac{N^2}{\mathcal{R}_c + \mathcal{R}_g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Number of turns | - |
| \(I\) | Coil current | A |
| \(l_c\) | Mean magnetic path length in the core | m |
| \(A_c\) | Core cross-section area | m² |
| \(\mu_r\) | Relative permeability of the core | - |
| \(l_g\) | Air gap length (0 for none) | m |
| \(\text{fringing}\) | Gap fringing | - |
| \(\mathcal{F}\) | Magnetomotive force NI | A |
| \(\mathcal{R}_c\) | Core reluctance | A/Wb |
| \(\mathcal{R}_g\) | Gap reluctance | A/Wb |
| \(\Phi\) | Flux | Wb |
| \(B_c\) | Flux density in the core | T |
| \(H_c\) | Field strength in the core | A/m |
| \(L\) | Inductance N²/ℛ | H |
| \(W\) | Stored energy ½LI² | J |
Method and standards
Series magnetic circuit with constant permeability.
Where it is used
- Gapped inductors and chokes, transformer and relay cores.
- Electromagnets and actuators.
Common mistakes
- Ignoring the gap, which usually dominates.
- Using the result above saturation.
Assumptions and limits
- Linear iron, uniform flux in the core.
References
- Magnetic circuit analysis with reluctances in series
Questions and answers
Why add an air gap to an inductor core?
The gap dominates the reluctance, so the inductance depends little on the iron's variable permeability and the core saturates at a much higher current.
When does fringing matter?
When the gap is not small compared with the pole size: the flux bulges out, the effective gap area grows and the inductance rises by a few to tens of per cent.
What do the defaults represent?
An illustrative 500-turn coil at 2 A on a 30 × 30 mm silicon-steel core (μr 3,000) with a 400 mm path and a 1 mm gap.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Hayt and Buck, Engineering Electromagnetics, 8th ed. (McGraw-Hill, 2012), sec. 8.8