FireCADCalc

Magnetic Circuit with Air Gap: Reluctance, Flux and Inductance

Core and air-gap reluctance, flux, flux density, field strength and inductance of a coil on an iron core with an air gap, with optional gap fringing.

Inputs

Examples: Illustrative: 500 turns, 2 A, 30 x 30 mm core, 400 mm path, mu_r 3000, 1 mm gap with fringingUngapped toroid: 200 turns, 0.5 A, 150 mm path, 1 cm2, mu_r 5000Choke: 100 turns, 10 A, 20 x 20 mm, 2 mm gap, no fringing (saturation warning)

Accepted: 1 to 1,000,000
Accepted: 1E-6 to 100,000 A
Accepted: 1 to 20,000 mm
Accepted: 0.001 to 20,000 cm²
Accepted: 1 to 1,000,000
Accepted: 0 to 100 mm

Results

Linear magnetic circuit: constant permeability, all flux confined to the core except the fringing at the gap. μ₀ = 4π × 10⁻⁷ H/m.

Magnetomotive force NI1,000.0A
Core reluctance119,366A/Wb
Gap reluctance3,978,874A/Wb
Flux0.24401mWb
Flux density in the core0.61002T
Field strength in the core242.72A/m
Inductance N²/ℛ2.4401mH
Stored energy ½LI²0.12200J

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 500 turns, 2 A, 30 x 30 mm core, 400 mm path, mu_r 3000, 1 mm gap with fringing. The inputs, in the units selected above:

InputValue
Number of turns500.00 -
Coil current2.0000 A
Mean magnetic path length in the core400.00 mm
Core cross-section area9.0000 cm²
Relative permeability of the core3,000.0 -
Air gap length (0 for none)1.0000 mm
Gap fringingAdd the gap length to each side of a square pole

Applying the formula below gives:

ResultValue
Magnetomotive force NI1,000.0 A
Core reluctance117,893 A/Wb
Gap reluctance828,069 A/Wb
Flux1.0571 mWb
Flux density in the core1.1746 T
Field strength in the core311.57 A/m
Inductance N²/ℛ264.28 mH
Stored energy ½LI²0.52856 J

Open this example in the calculator and change any input.

Formula

\(\mathcal{R}_c = \frac{l_c}{\mu_0\mu_r A_c}, \quad \mathcal{R}_g = \frac{l_g}{\mu_0 A_g}, \quad \Phi = \frac{NI}{\mathcal{R}_c + \mathcal{R}_g}, \quad L = \frac{N^2}{\mathcal{R}_c + \mathcal{R}_g}\)

Variables

Symbol Meaning SI unit
\(N\) Number of turns -
\(I\) Coil current A
\(l_c\) Mean magnetic path length in the core m
\(A_c\) Core cross-section area m²
\(\mu_r\) Relative permeability of the core -
\(l_g\) Air gap length (0 for none) m
\(\text{fringing}\) Gap fringing -
\(\mathcal{F}\) Magnetomotive force NI A
\(\mathcal{R}_c\) Core reluctance A/Wb
\(\mathcal{R}_g\) Gap reluctance A/Wb
\(\Phi\) Flux Wb
\(B_c\) Flux density in the core T
\(H_c\) Field strength in the core A/m
\(L\) Inductance N²/ℛ H
\(W\) Stored energy ½LI² J

Method and standards

Series magnetic circuit with constant permeability.

Where it is used

  • Gapped inductors and chokes, transformer and relay cores.
  • Electromagnets and actuators.

Common mistakes

  • Ignoring the gap, which usually dominates.
  • Using the result above saturation.

Assumptions and limits

  • Linear iron, uniform flux in the core.

References

  • Magnetic circuit analysis with reluctances in series

Questions and answers

Why add an air gap to an inductor core?

The gap dominates the reluctance, so the inductance depends little on the iron's variable permeability and the core saturates at a much higher current.

When does fringing matter?

When the gap is not small compared with the pole size: the flux bulges out, the effective gap area grows and the inductance rises by a few to tens of per cent.

What do the defaults represent?

An illustrative 500-turn coil at 2 A on a 30 × 30 mm silicon-steel core (μr 3,000) with a 400 mm path and a 1 mm gap.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hayt and Buck, Engineering Electromagnetics, 8th ed. (McGraw-Hill, 2012), sec. 8.8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.