FireCADCalc

Resistance Heating Element: Wire Length and Surface Load

Hot and cold resistance, wire length, surface loading and mass of a resistance heating element for a power and voltage, from wire diameter and resistivity.

Inputs

Examples: Illustrative 2 kW NiCr elementFeCrAl kiln element 3 kW12 V 50 W heater

Accepted: 0.001 to 10,000 kW
Accepted: 1 to 100,000 V
Accepted: 0.01 to 20 mm
Accepted: 0.01 to 10 Ω·mm²/m
Accepted: 0.5 to 20
Accepted: 1,000 to 25,000 kg/m³

Results

The element must have R = V²/P at its working temperature. Its cold resistance is that divided by the alloy's temperature factor C_t (about 1.02–1.07 for NiCr 80/20 at 600–1,000 °C, larger for FeCrAl and much larger for pure metals), and the length follows from R = ρL/A. Surface loading P/(πdL) decides the wire temperature and life: a few W/cm² for open coils in still air, 10–20 W/cm² in forced air or sheathed elements, more for immersion. A thicker wire gives a longer element and lower surface loading.

Resistance at operating temperature17.633Ω
Resistance at 20 °C16.635Ω
Wire length23.067m
Surface loading2.5874W/cm²
Wire mass329.29g
Current13.043A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 kW NiCr element. The inputs, in the units selected above:

InputValue
Element power2.0000 kW
Supply voltage230.00 V
Wire diameter0.60000 mm
Resistivity at 20 °C1.0900 Ω·mm²/m
Hot/cold resistance factor at operating temperature1.0400 -
Wire density8,400.0 kg/m³

Applying the formula below gives:

ResultValue
Resistance at operating temperature26.450 Ω
Resistance at 20 °C25.433 Ω
Wire length6.5972 m
Surface loading16.083 W/cm²
Wire mass15.669 g
Current8.6957 A

Open this example in the calculator and change any input.

Formula

\(R_{hot} = \frac{V^2}{P}, \quad L = \frac{R_{hot}}{C_t}\frac{\pi d^2}{4\rho_{20}}, \quad q = \frac{P}{\pi dL}\)

Variables

Symbol Meaning SI unit
\(P\) Element power W
\(V\) Supply voltage V
\(d\) Wire diameter m
\(\rho_{20}\) Resistivity at 20 °C Ω·m
\(C_t\) Hot/cold resistance factor at operating temperature -
\(\rho_m\) Wire density kg/m³
\(R_{hot}\) Resistance at operating temperature Ω
\(R_{20}\) Resistance at 20 °C Ω
\(L\) Wire length m
\(q\) Surface loading W/m²
\(m\) Wire mass kg
\(I\) Current A

Method and standards

Heater wire.

Where it is used

  • Designing or rewinding heating elements.
  • Checking element surface loading.

Common mistakes

  • Ignoring the temperature factor.
  • Exceeding the alloy's surface loading.

Assumptions and limits

  • Uniform wire; steady operating temperature.

References

  • Resistance and surface loading of heating elements

Questions and answers

Why is the hot/cold factor needed?

Resistivity rises with temperature; ignoring it gives slightly too much power when the element is hot.

How do I pick the wire diameter?

Choose one that keeps surface loading within the alloy's limit for the application; thicker wire lasts longer.

What do the defaults represent?

An illustrative 2 kW, 230 V element of 0.6 mm NiCr 80/20 wire (1.09 Ω·mm²/m, C_t = 1.04).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hayt and Kemmerly, Engineering Circuit Analysis, 8th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.