FireCADCalc

Electromagnet Pull Force across an Air Gap

Gap flux density and pull force of a DC electromagnet or relay on its armature from turns, current, gap, pole area and the core path, by Maxwell's pull formula.

Inputs

Examples: Illustrative: U-core, 800 turns at 1.5 A, two 20 x 20 mm poles, 0.5 mm gapsRelay: 3000 turns at 50 mA, single 0.3 mm gap, 5 x 5 mm poleLifting magnet near contact: 0.1 mm gaps (saturation warning)

Accepted: 1 to 1,000,000
Accepted: 1E-6 to 10,000 A
Accepted: 0.001 to 100 mm
Accepted: 0.001 to 10,000 cm²
Accepted: 1 to 2
Accepted: 0 to 10,000 mm
Accepted: 1 to 1,000,000

Results

Maxwell's pull F = B²A/(2μ₀) per pole, with the iron path of the same section as the poles and no fringing or leakage; the force rises steeply as the gap closes.

Flux density in the gap1.3709T
Magnetic pressure on the pole face747.75kPa
Total pull force598.20N
Coil inductance at this gap292.45mH

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: U-core, 800 turns at 1.5 A, two 20 x 20 mm poles, 0.5 mm gaps. The inputs, in the units selected above:

InputValue
Number of turns800.00 -
Coil current1.5000 A
Air gap at each pole0.50000 mm
Pole face area (each)4.0000 cm²
Number of gaps in the flux path (1 or 2)2.0000 -
Iron path length (core and armature)200.00 mm
Relative permeability of the iron2,000.0 -

Applying the formula below gives:

ResultValue
Flux density in the gap1.3709 T
Magnetic pressure on the pole face747.75 kPa
Total pull force598.20 N
Coil inductance at this gap292.45 mH

Open this example in the calculator and change any input.

Formula

\(B_g = \frac{\mu_0 NI}{n_p g + l_c/\mu_r}, \quad F = n_p\frac{B_g^2A}{2\mu_0}\)

Variables

Symbol Meaning SI unit
\(N\) Number of turns -
\(I\) Coil current A
\(g\) Air gap at each pole m
\(A\) Pole face area (each) m²
\(n_p\) Number of gaps in the flux path (1 or 2) -
\(l_c\) Iron path length (core and armature) m
\(\mu_r\) Relative permeability of the iron -
\(B_g\) Flux density in the gap T
\(B^2/2\mu_0\) Magnetic pressure on the pole face Pa
\(F\) Total pull force N
\(L\) Coil inductance at this gap H

Method and standards

Magnetic pull from field energy (Maxwell stress).

Where it is used

  • Lifting magnets, holding magnets and door locks.
  • Relays, contactors and solenoid actuators.

Common mistakes

  • Using the gap at the closed position for the pick-up force.
  • Ignoring saturation at small gaps.

Assumptions and limits

  • Uniform gap field, no fringing or leakage, linear iron.

References

  • Maxwell's pull formula with a series magnetic circuit

Questions and answers

Why does the force rise so fast as the gap closes?

The flux density is inversely proportional to the gap, and the force goes as B²: halving the gap roughly quadruples the pull until the iron saturates.

What is the maximum pull per area?

About 0.9–1 MPa (90–100 N/cm²) at 1.5 T, the practical limit set by saturation of soft iron.

What do the defaults represent?

An illustrative U-core electromagnet of 800 turns at 1.5 A with two 20 × 20 mm poles and 0.5 mm gaps.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hayt and Buck, Engineering Electromagnetics, 8th ed. (McGraw-Hill, 2012), sec. 8.9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.