FireCADCalc

Batch Dyeing: Liquor Ratio, Dye and Chemicals

Water, dye and chemicals for batch dyeing from fabric mass, liquor ratio, dye % on weight of fabric and auxiliaries in g/L, with the heat to raise the bath.

Food, dairy and textile

Inputs

Examples: 500 kg cotton, 1:8, 2 % reactivePolyester HT 1:6

Results

Low-liquor-ratio machines (1:4–1:6) save water, salt and heat in proportion to the bath volume.

Bath volume4,000.0L
Dye10.000kg
Salt240.00kg
Alkali60.000kg
Heat to raise the bath608.90MJ

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 500 kg cotton, 1:8, 2 % reactive. The inputs, in the units selected above:

InputValue
Fabric (dry)500.00 kg
Liquor ratio (L of bath per kg fabric)8.0000 -
Dye on weight of fabric2.0000 %
Salt60.000 g/L
Soda ash or alkali15.000 g/L
Bath fill temperature25.000 °C
Dyeing temperature60.000 °C

Applying the formula below gives:

ResultValue
Bath volume4,000.0 L
Dye10.000 kg
Salt240.00 kg
Alkali60.000 kg
Heat to raise the bath608.90 MJ

Open this example in the calculator and change any input.

Formula

\(V = M\cdot MLR, \quad m_d = d\,M, \quad m_s = c_sV, \quad m_a = c_aV, \quad Q = V\rho c_w(T_2 - T_1) + Mc_f(T_2 - T_1)\)

Variables

Symbol Meaning SI unit
\(M\) Fabric (dry) kg
\(MLR\) Liquor ratio (L of bath per kg fabric) -
\(d\) Dye on weight of fabric -
\(c_s\) Salt kg/m³
\(c_a\) Soda ash or alkali kg/m³
\(T_1\) Bath fill temperature K
\(T_2\) Dyeing temperature K
\(V\) Bath volume m³
\(m_d\) Dye kg
\(m_s\) Salt kg
\(m_a\) Alkali kg
\(Q\) Heat to raise the bath J
\(\rho\) Bath density, 1000 kg/m³ kg/m³
\(c_w\) Specific heat of the bath, 4.1868 kJ/(kg·K) J/(kg·K)
\(c_f\) Specific heat of the fabric, 1.3 kJ/(kg·K) J/(kg·K)

Method and standards

Recipe definitions and sensible heat.

Where it is used

  • Dye house recipes and utility budgets.

Common mistakes

  • Dosing salt on fabric weight.
  • Ignoring fabric moisture.

Assumptions and limits

  • Bath density 1 kg/L and water specific heat constant.
  • The heat is for the bath and fabric only: the machine's own heat capacity, radiation losses and, for high-temperature polyester dyeing up to 140 °C, the slightly higher specific heat of hot water are not counted, so the real steam demand is higher.

References

  • Definitions and mass and energy balances; fabric specific heat taken as 1.3 kJ/(kg·K)

Questions and answers

What is % owf?

Dye as a percentage of the weight of fabric; chemicals are dosed on the bath volume in g/L.

Why does liquor ratio matter?

Water, salt, alkali and heat all scale with it.

What liquor ratio is usual?

Jets 1:5–1:10, winches 1:15–1:20.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.