Arrhenius Equation: Rate Constant at Another Temperature

Rate constant of a reaction at a new temperature from its value at a known temperature and the activation energy, with the pre-exponential factor and half-life.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 1e-4 1/s at 25 °C, 50 kJ/mol, to 35 °C2.5e-3 1/s at 80 °C, 85 kJ/mol, to 100 °C0.05 1/min at 37 °C, 30 kJ/mol, to 4 °C

For other orders enter the constant in your own units; k₂ comes out in the same units and the half-life does not apply.

Results

Rate constant at T₂2.0856e-041/s
Rate ratio0.25027
Pre-exponential factor94.0241/s
Half-life at T₂ (first order)55.391min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1e-4 1/s at 25 °C, 50 kJ/mol, to 35 °C. The inputs, in the units selected above:

InputValue
Rate constant at T₁ (first order)1.0000e-04 1/s
Temperature at which k₁ was measured25.000 °C
Activation energy50.000 kJ/mol
New temperature35.000 °C

Applying the formula below gives:

ResultValue
Rate constant at T₂1.9243e-04 1/s
Rate ratio1.9243
Pre-exponential factor57,494 1/s
Half-life at T₂ (first order)60.036 min

Open this example in the calculator and change any input.

Formula

\(k_2 = k_1 \exp\left[-\frac{E_a}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)\right]\)

\(A = k_1 e^{E_a/(R T_1)}, \quad t_{1/2} = \frac{\ln 2}{k_2}\)

Variables

Symbol Meaning SI unit
\(k_1\) Rate constant at T₁ (first order) 1/s
\(T_1\) Temperature at which k₁ was measured K
\(E_a\) Activation energy J/mol
\(T_2\) New temperature K
\(k_2\) Rate constant at T₂ 1/s
\(k_2 / k_1\) Rate ratio -
\(A\) Pre-exponential factor 1/s
\(t_{1/2}\) Half-life at T₂ (first order) s
\(R\) Universal gas constant J/(mol·K)

Method and standards

The Arrhenius relation between rate constant and absolute temperature with the CODATA gas constant.

Where it is used

  • Scaling reaction times between temperatures.
  • Shelf-life and accelerated ageing estimates.
  • Corrosion and degradation rates.

Common mistakes

  • Using °C instead of K.
  • Using J/mol and kJ/mol mixed.
  • Extrapolating far outside the measured range.

Assumptions and limits

  • Constant activation energy over the range.
  • The half-life ln 2/k₂ applies to a first-order reaction only; for other orders ignore it.
  • At extreme activation energies and low temperatures the pre-exponential factor overflows and is not shown.

References

  • S. Arrhenius (1889); CODATA gas constant

Questions and answers

How much faster is a 50 kJ/mol reaction at 35 °C than at 25 °C?

1.92 times: the old rule of a doubling per 10 K holds near room temperature for about 50 kJ/mol.

What is the half-life?

For a first-order reaction ln 2/k: 3 600 s (1 hour) at 35 °C in that example.

Can I use it for other orders?

Yes for k, in your own units; the half-life shown is for first order only.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.