Worked example
Example: Liquid propane at 25 °C, 25 mm hole. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid temperature in the vessel | 25.000 °C |
| Normal boiling point | -42.050 °C |
| Mean liquid heat capacity | 2.6000 kJ/(kg·K) |
| Latent heat at the boiling point | 426.00 kJ/kg |
| Change in specific volume on vaporisation (v_g − v_f) at the vessel condition | 0.040000 m³/kg |
| Hole diameter | 25.400 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flash fraction (simple balance) | 40.923 % |
| Flash fraction (integrated, constant latent heat) | 33.584 % |
| Two-phase mass flux (equilibrium, choked) | 12,096 kg/(m²·s) |
| Two-phase discharge rate | 6.1292 kg/s |
Open this example in the calculator and change any input.
Formula
\(f_v = \frac{\bar C_p(T_0 - T_b)}{\Delta H_v}, \quad f_v = 1 - \exp\left[-\frac{\bar C_p(T_0 - T_b)}{\Delta H_v}\right], \quad Q_m = A\frac{\Delta H_v}{v_{fg}}\sqrt{\frac{1}{\bar C_pT_0}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_0\) | Liquid temperature in the vessel | K |
| \(T_b\) | Normal boiling point | K |
| \(\bar C_p\) | Mean liquid heat capacity | J/(kg·K) |
| \(\Delta H_v\) | Latent heat at the boiling point | J/kg |
| \(v_{fg}\) | Change in specific volume on vaporisation (v_g − v_f) at the vessel condition | m³/kg |
| \(d\) | Hole diameter | m |
| \(f_v\) | Flash fraction (simple balance) | - |
| \(G\) | Two-phase mass flux (equilibrium, choked) | kg/(m²·s) |
| \(Q_m\) | Two-phase discharge rate | kg/s |
Method and standards
Energy balance on adiabatic flashing and the equilibrium two-phase discharge (Fauske and Epstein) as given by Crowl and Louvar.
Where it is used
- LPG, ammonia and chlorine release scenarios.
- Sizing catch tanks and estimating cloud size.
Common mistakes
- Using the vessel pressure boiling point instead of the normal boiling point.
- Ignoring spray carried with the flash.
Assumptions and limits
- Adiabatic flashing; equilibrium flow.
References
- Crowl and Louvar
- Chemical Process Safety: Fundamentals with Applications
- 2nd ed. (Prentice Hall, 2002)
- ch. 4
- eqs. 4-90
- 4-93 and 4-104 (Fauske and Epstein equilibrium rate model)
Questions and answers
Why two flash fractions?
The simple balance assumes constant heat capacity and latent heat for the whole drop in temperature; the integrated form accounts for the liquid cooling as it flashes and is always a little lower.
Where do I get v_fg?
From the liquid and saturated vapour densities at the vessel temperature: v_fg = 1/ρ_v − 1/ρ_l.
What do the defaults represent?
Liquid propane at 25 °C (boiling point −42 °C) leaking through a 25 mm hole.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.