FireCADCalc

Flash Fraction and Two-Phase Release of a Superheated Liquid

Fraction of a pressurised liquid that flashes to vapour on release, by the simple and the integrated balance, and the choked two-phase discharge through a hole.

Process steam and utilitiesDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Liquid propane at 25 °C, 25 mm holeAmmonia at 20 °C, 10 mmButane at 30 °C

Results

The flashing liquid also carries off spray: the airborne mass is often taken as about twice the flash fraction. The two-phase flux is the equilibrium rate model for discharge through holes or pipes longer than about 10 cm; a sharp hole in a thin wall passes more, nearer the liquid rate.

A screening estimate for training and early design, not a hazard or risk study.

Flash fraction (simple balance)18.303%
Flash fraction (integrated, constant latent heat)16.725%
Two-phase mass flux (equilibrium, choked)8,978.1kg/(m²·s)
Two-phase discharge rate0.70514kg/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Liquid propane at 25 °C, 25 mm hole. The inputs, in the units selected above:

InputValue
Liquid temperature in the vessel25.000 °C
Normal boiling point-42.050 °C
Mean liquid heat capacity2.6000 kJ/(kg·K)
Latent heat at the boiling point426.00 kJ/kg
Change in specific volume on vaporisation (v_g − v_f) at the vessel condition0.040000 m³/kg
Hole diameter25.400 mm

Applying the formula below gives:

ResultValue
Flash fraction (simple balance)40.923 %
Flash fraction (integrated, constant latent heat)33.584 %
Two-phase mass flux (equilibrium, choked)12,096 kg/(m²·s)
Two-phase discharge rate6.1292 kg/s

Open this example in the calculator and change any input.

Formula

\(f_v = \frac{\bar C_p(T_0 - T_b)}{\Delta H_v}, \quad f_v = 1 - \exp\left[-\frac{\bar C_p(T_0 - T_b)}{\Delta H_v}\right], \quad Q_m = A\frac{\Delta H_v}{v_{fg}}\sqrt{\frac{1}{\bar C_pT_0}}\)

Variables

Symbol Meaning SI unit
\(T_0\) Liquid temperature in the vessel K
\(T_b\) Normal boiling point K
\(\bar C_p\) Mean liquid heat capacity J/(kg·K)
\(\Delta H_v\) Latent heat at the boiling point J/kg
\(v_{fg}\) Change in specific volume on vaporisation (v_g − v_f) at the vessel condition m³/kg
\(d\) Hole diameter m
\(f_v\) Flash fraction (simple balance) -
\(G\) Two-phase mass flux (equilibrium, choked) kg/(m²·s)
\(Q_m\) Two-phase discharge rate kg/s

Method and standards

Energy balance on adiabatic flashing and the equilibrium two-phase discharge (Fauske and Epstein) as given by Crowl and Louvar.

Where it is used

  • LPG, ammonia and chlorine release scenarios.
  • Sizing catch tanks and estimating cloud size.

Common mistakes

  • Using the vessel pressure boiling point instead of the normal boiling point.
  • Ignoring spray carried with the flash.

Assumptions and limits

  • Adiabatic flashing; equilibrium flow.

References

  • Crowl and Louvar
  • Chemical Process Safety: Fundamentals with Applications
  • 2nd ed. (Prentice Hall, 2002)
  • ch. 4
  • eqs. 4-90
  • 4-93 and 4-104 (Fauske and Epstein equilibrium rate model)

Questions and answers

Why two flash fractions?

The simple balance assumes constant heat capacity and latent heat for the whole drop in temperature; the integrated form accounts for the liquid cooling as it flashes and is always a little lower.

Where do I get v_fg?

From the liquid and saturated vapour densities at the vessel temperature: v_fg = 1/ρ_v − 1/ρ_l.

What do the defaults represent?

Liquid propane at 25 °C (boiling point −42 °C) leaking through a 25 mm hole.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.