FireCADCalc

Deflagration Index K_G or K_St (Cubic Law)

Deflagration index from the maximum rate of pressure rise in a test vessel and its volume (K = (dP/dt)max·V^⅓), and the rate expected in another closed vessel.

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Dust in 20 L sphere, 600 bar/s, to 10 m³Gas in 1 m³, 100 bar/s, to 50 m³

bar/s

Results

The cubic law needs geometrically similar vessels and the same turbulence. Vent sizing follows NFPA 68 or EN 14491, not this calculator. Screening estimate only, not a safety study or a basis for protective design.

St classes apply to dusts only; for a gas K is K_G and the class has no meaning. Class St 0 (no explosion) is found by test, not from a K above zero.

Deflagration index (bar·m/s)100.00
Expected max rate in V₂ (bar/s)27.144
Dust class St by K_St (dusts only; 1: ≤200, 2: ≤300, 3: >300)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Dust in 20 L sphere, 600 bar/s, to 10 m³. The inputs, in the units selected above:

InputValue
Maximum rate of pressure rise in the test600.00 -
Test vessel volume20.000 L
Volume of the vessel of interest10.000 m³

Applying the formula below gives:

ResultValue
Deflagration index (bar·m/s)162.87
Expected max rate in V₂ (bar/s)75.595
Dust class St by K_St (dusts only; 1: ≤200, 2: ≤300, 3: >300)1.0000

Open this example in the calculator and change any input.

Formula

\(K = \left(\frac{dP}{dt}\right)_{max}V^{1/3}, \quad \left(\frac{dP}{dt}\right)_2 = \frac{K}{V_2^{1/3}}\)

Variables

Symbol Meaning SI unit
\((dP/dt)_{max}\) Maximum rate of pressure rise in the test -
\(V\) Test vessel volume m³
\(V_2\) Volume of the vessel of interest m³
\(K\) Deflagration index (bar·m/s) -
\((dP/dt)_2\) Expected max rate in V₂ (bar/s) -
\(St\) Dust class St by K_St (dusts only; 1: ≤200, 2: ≤300, 3: >300) -

Method and standards

Cubic law.

Where it is used

  • Comparing dust and gas explosion severity.

Common mistakes

  • Using it for vent sizing.
  • Comparing tests from different vessel sizes or ignition energies.

Assumptions and limits

  • Similar geometry and turbulence.
  • The St class is for dusts; it is shown for any K but has no meaning for a gas K_G. St 0 (no explosion) comes from a test that shows no explosion, so it never results from a positive rate here.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 23 (deflagration index K_G, K_St = (dP/dt)max V^⅓; dust explosion classes)

Questions and answers

What is K_St?

The maximum rate of pressure rise normalised by vessel size; it ranks how violently a dust explodes.

What are the dust classes?

St 1 up to 200, St 2 up to 300, St 3 above 300 bar·m/s.

Why does a bigger vessel see a slower rise?

The flame takes longer to cross it: dP/dt falls as V^−⅓.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.