FireCADCalc

Solution Gas-Oil Ratio and Bo by Vasquez–Beggs

Gas solubility and oil formation volume factor of saturated crude at a pressure by the Vasquez–Beggs correlation, with gas gravity corrected to 100 psig separation.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 35 °API, 2000 psia, 180 °F25 °API heavy, 1500 psia, 150 °F, 200 psig separatorAhmed oil 1 at its bubble point

Results

Valid for saturated oil (pressure at or below the bubble point). Coefficients change at 30 °API. With unknown separator conditions, enter 114.7 psia so that no correction is made.

Gas gravity at 100 psig separator0.82897
Solution gas-oil ratio256.33scf/STB
Oil formation volume factor1.1548

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 35 °API, 2000 psia, 180 °F. The inputs, in the units selected above:

InputValue
Pressure (at or below the bubble point)2,000.0 psi
Temperature82.406 °C
Oil gravity35.000 -
Gas gravity at the separator (air = 1)0.75000 -
Separator pressure (absolute)114.70 psi
Separator temperature15.739 °C

Applying the formula below gives:

ResultValue
Gas gravity at 100 psig separator0.75000
Solution gas-oil ratio409.43 scf/STB
Oil formation volume factor1.2559

Open this example in the calculator and change any input.

Formula

\(R_s = C_1\gamma_{gs}p^{C_2}\exp\left(\frac{C_3\,\text{API}}{T}\right), \quad B_o = 1 + C_1'R_s + (T - 520)\frac{\text{API}}{\gamma_{gs}}(C_2' + C_3'R_s)\)

\(\gamma_{gs} = \gamma_g\left[1 + 5.912\times10^{-5}\,\text{API}\,(T_{sep} - 460)\log\frac{p_{sep}}{114.7}\right]\)

Variables

Symbol Meaning SI unit
\(p\) Pressure (at or below the bubble point) Pa
\(T\) Temperature K
\(\text{API}\) Oil gravity -
\(\gamma_g\) Gas gravity at the separator (air = 1) -
\(p_{sep}\) Separator pressure (absolute) Pa
\(T_{sep}\) Separator temperature K
\(\gamma_{gs}\) Gas gravity at 100 psig separator -
\(R_s\) Solution gas-oil ratio m³/m³
\(B_o\) Oil formation volume factor -

Method and standards

Vasquez–Beggs in field units (psia, °R, scf/STB): API ≤ 30: C₁ = 0.0362, C₂ = 1.0937, C₃ = 25.7240, C₁′ = 4.677×10⁻⁴, C₂′ = 1.751×10⁻⁵, C₃′ = −1.811×10⁻⁸; API > 30: 0.0178, 1.1870, 23.931, 4.670×10⁻⁴, 1.100×10⁻⁵, 1.337×10⁻⁹.

Where it is used

  • PVT estimates for production engineering.
  • Separator and tank design.

Common mistakes

  • Using it above the bubble point.
  • Forgetting the separator correction.

Assumptions and limits

  • Saturated black oil.

References

  • Ahmed
  • Reservoir Engineering Handbook
  • 5th ed. (Gulf Professional Publishing, 2019)
  • ch. 2
  • eqs. 2-70
  • 2-71 and 2-85 (Vasquez and Beggs, 1980)

Questions and answers

Why correct the gas gravity?

Vasquez and Beggs built the correlation on gas from a 100 psig separator; gas from other separator conditions has a different gravity.

Is this better than Standing?

It was fitted to a much larger and more varied data set (over 5,000 points), so it is often preferred for general crudes.

What do the defaults represent?

A 35 °API crude at 2,000 psia and 180 °F with 0.75-gravity gas from a 100 psig separator.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.