FireCADCalc

TEG Gas Dehydration: Water Removed, Glycol Rate and Contactor Diameter

Water to remove from natural gas, TEG circulation from the glycol-to-water ratio, and glycol contactor diameter by Souders–Brown at operating pressure.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: 20 MMscfd, 60 to 7 lb/MMscf, 1,000 psia5 MMscfd at 600 psia, 4 gal/lb

Results

Water contents come from a water-content chart or a measured dew point. The industry rule is 3 US gal TEG per lb of water removed (range 2–6); operate 10–30 % above the minimum rate. The K factor is the GPSA mist-pad fit given by Mokhatab, reduced for glycol; check tray or packing loading with the vendor.

Water removed7.8434kg/h
Minimum TEG circulation261.82L/h
Souders–Brown coefficient0.064322m/s
Maximum superficial gas velocity0.37327m/s
Minimum contactor inside diameter363.01mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 MMscfd, 60 to 7 lb/MMscf, 1,000 psia. The inputs, in the units selected above:

InputValue
Gas flow (standard)20.000 MMscfd
Water content of the inlet gas60.000 lb/MMscf
Water content required at the outlet7.0000 lb/MMscf
Glycol-to-water ratio3.0000 US gal/lb
Contactor pressure (absolute)1,000.00 psi
Contactor temperature37.778 °C
Compressibility factor0.87000 -
Gas specific gravity0.65000 -
Lean glycol density1,110.0 kg/m³
K-factor reduction for glycol (0.6–0.8)0.70000 -

Applying the formula below gives:

ResultValue
Water removed20.034 kg/h
Minimum TEG circulation501.57 L/h
Souders–Brown coefficient0.055787 m/s
Maximum superficial gas velocity0.23821 m/s
Minimum contactor inside diameter694.57 mm

Open this example in the calculator and change any input.

Formula

\(\dot W_r = Q_g(W_{in} - W_{out}), \quad Q_{TEG} = G\dot W_r, \quad V_{max} = K_{SB}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad D = \sqrt{\frac{4Q_a}{\pi V_{max}}}\)

\(K_{SB} = f\,[0.35 - 0.0001(P_{psig} - 100)]\ \text{ft/s}\)

Variables

Symbol Meaning SI unit
\(Q_g\) Gas flow (standard) Nm³/s
\(W_{in}\) Water content of the inlet gas kg/m³
\(W_{out}\) Water content required at the outlet kg/m³
\(G\) Glycol-to-water ratio m³/kg
\(P\) Contactor pressure (absolute) Pa
\(T\) Contactor temperature K
\(Z\) Compressibility factor -
\(SG\) Gas specific gravity -
\(\rho_L\) Lean glycol density kg/m³
\(f\) K-factor reduction for glycol (0.6–0.8) -
\(\dot W_r\) Water removed kg/s
\(Q_{TEG}\) Minimum TEG circulation m³/s
\(K_{SB}\) Souders–Brown coefficient m/s
\(V_{max}\) Maximum superficial gas velocity m/s
\(D\) Minimum contactor inside diameter m

Method and standards

Water balance and Souders–Brown flooding velocity.

Where it is used

  • Gas plant and compressor station dehydration.
  • Checking an existing contactor for higher throughput.

Common mistakes

  • Mixing standard and actual gas flows.
  • Using the outlet spec as a dew point without converting.

Assumptions and limits

  • Saturated inlet gas; mist-pad K fit.

References

  • Mokhatab
  • Poe and Speight
  • Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
  • ch. 9
  • eqs. 9-3 and 9-4
  • and ch. 5
  • eq. 5-8 (GPSA K factor)

Questions and answers

Why 7 lb/MMscf?

It is a common pipeline specification for water content in North America; other contracts set a dew point instead.

Does more glycol always dry the gas more?

Only up to a point; above about 3–5 gal/lb the gain is small and reboiler duty rises. Lean glycol purity matters more.

What do the defaults represent?

20 MMscfd of 0.65-gravity gas from 60 to 7 lb/MMscf at 1,000 psia and 100 °F, 3 gal TEG per lb.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.