Worked example
Example: 20 MMscfd, 60 to 7 lb/MMscf, 1,000 psia. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow (standard) | 20.000 MMscfd |
| Water content of the inlet gas | 60.000 lb/MMscf |
| Water content required at the outlet | 7.0000 lb/MMscf |
| Glycol-to-water ratio | 3.0000 US gal/lb |
| Contactor pressure (absolute) | 1,000.00 psi |
| Contactor temperature | 37.778 °C |
| Compressibility factor | 0.87000 - |
| Gas specific gravity | 0.65000 - |
| Lean glycol density | 1,110.0 kg/m³ |
| K-factor reduction for glycol (0.6–0.8) | 0.70000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water removed | 20.034 kg/h |
| Minimum TEG circulation | 501.57 L/h |
| Souders–Brown coefficient | 0.055787 m/s |
| Maximum superficial gas velocity | 0.23821 m/s |
| Minimum contactor inside diameter | 694.57 mm |
Open this example in the calculator and change any input.
Formula
\(\dot W_r = Q_g(W_{in} - W_{out}), \quad Q_{TEG} = G\dot W_r, \quad V_{max} = K_{SB}\sqrt{\frac{\rho_L - \rho_G}{\rho_G}}, \quad D = \sqrt{\frac{4Q_a}{\pi V_{max}}}\)
\(K_{SB} = f\,[0.35 - 0.0001(P_{psig} - 100)]\ \text{ft/s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_g\) | Gas flow (standard) | Nm³/s |
| \(W_{in}\) | Water content of the inlet gas | kg/m³ |
| \(W_{out}\) | Water content required at the outlet | kg/m³ |
| \(G\) | Glycol-to-water ratio | m³/kg |
| \(P\) | Contactor pressure (absolute) | Pa |
| \(T\) | Contactor temperature | K |
| \(Z\) | Compressibility factor | - |
| \(SG\) | Gas specific gravity | - |
| \(\rho_L\) | Lean glycol density | kg/m³ |
| \(f\) | K-factor reduction for glycol (0.6–0.8) | - |
| \(\dot W_r\) | Water removed | kg/s |
| \(Q_{TEG}\) | Minimum TEG circulation | m³/s |
| \(K_{SB}\) | Souders–Brown coefficient | m/s |
| \(V_{max}\) | Maximum superficial gas velocity | m/s |
| \(D\) | Minimum contactor inside diameter | m |
Method and standards
Water balance and Souders–Brown flooding velocity.
Where it is used
- Gas plant and compressor station dehydration.
- Checking an existing contactor for higher throughput.
Common mistakes
- Mixing standard and actual gas flows.
- Using the outlet spec as a dew point without converting.
Assumptions and limits
- Saturated inlet gas; mist-pad K fit.
References
- Mokhatab
- Poe and Speight
- Handbook of Natural Gas Transmission and Processing (Gulf Professional Publishing, 2006)
- ch. 9
- eqs. 9-3 and 9-4
- and ch. 5
- eq. 5-8 (GPSA K factor)
Questions and answers
Why 7 lb/MMscf?
It is a common pipeline specification for water content in North America; other contracts set a dew point instead.
Does more glycol always dry the gas more?
Only up to a point; above about 3–5 gal/lb the gain is small and reboiler duty rises. Lean glycol purity matters more.
What do the defaults represent?
20 MMscfd of 0.65-gravity gas from 60 to 7 lb/MMscf at 1,000 psia and 100 °F, 3 gal TEG per lb.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.