Worked example
Example: 30 °API, 350 scf/STB, 200 °F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solution gas-oil ratio at the bubble point | 350.00 scf/STB |
| Solution gas gravity (air = 1) | 0.75000 - |
| Oil gravity | 30.000 - |
| Reservoir temperature | 93.517 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bubble-point pressure | 1,890.3 psi |
| Oil formation volume factor at the bubble point | 1.2212 |
| Oil specific gravity | 0.87616 |
Open this example in the calculator and change any input.
Formula
\(p_b = 18.2\left[\left(\frac{R_s}{\gamma_g}\right)^{0.83}10^{a} - 1.4\right], \quad a = 0.00091(T - 460) - 0.0125\,\text{API}\)
\(B_o = 0.9759 + 0.000120\left[R_s\left(\frac{\gamma_g}{\gamma_o}\right)^{0.5} + 1.25(T - 460)\right]^{1.2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R_s\) | Solution gas-oil ratio at the bubble point | m³/m³ |
| \(\gamma_g\) | Solution gas gravity (air = 1) | - |
| \(\text{API}\) | Oil gravity | - |
| \(T\) | Reservoir temperature | K |
| \(p_b\) | Bubble-point pressure | Pa |
| \(B_{ob}\) | Oil formation volume factor at the bubble point | - |
| \(\gamma_o\) | Oil specific gravity | - |
Method and standards
Standing's correlations in field units (psia, scf/STB, °R).
Where it is used
- Reservoir fluid screening without a PVT report.
- Well and facility design.
Common mistakes
- Using separator gas gravity without adjustment.
- Applying to volatile oils.
Assumptions and limits
- Black oil; hydrocarbon gas.
References
- Ahmed
- Reservoir Engineering Handbook
- 5th ed. (Gulf Professional Publishing, 2019)
- ch. 2
- eqs. 2-76
- 2-77 and 2-84 (Standing, 1981)
Questions and answers
What is the bubble point?
The pressure at which the first gas bubble leaves the oil; above it the oil is undersaturated.
How accurate is Standing's correlation?
Typically within about 5 % for the crudes it was built on; check with a laboratory PVT report when one exists.
What do the defaults represent?
A 30 °API oil with 350 scf/STB of 0.75-gravity gas at 200 °F.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.