Worked example
Example: NPS 16, 14 and 12 in series. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Length of segment 1 | 16.000 km |
| Inside diameter of segment 1 | 393.70 mm |
| Length of segment 2 | 24.000 km |
| Inside diameter of segment 2 | 342.90 mm |
| Length of segment 3 (0 = none) | 16.000 km |
| Inside diameter of segment 3 | 292.10 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equivalent length of segment 2 | 47.885 km |
| Equivalent length of segment 3 | 71.169 km |
| Total equivalent length in diameter D₁ | 135.05 km |
Open this example in the calculator and change any input.
Formula
\(L_e = L_1 + L_2\left(\frac{D_1}{D_2}\right)^5 + L_3\left(\frac{D_1}{D_3}\right)^5\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Length of segment 1 | m |
| \(D_1\) | Inside diameter of segment 1 | m |
| \(L_2\) | Length of segment 2 | m |
| \(D_2\) | Inside diameter of segment 2 | m |
| \(L_3\) | Length of segment 3 (0 = none) | m |
| \(D_3\) | Inside diameter of segment 3 | m |
| \(L_{e2}\) | Equivalent length of segment 2 | m |
| \(L_{e3}\) | Equivalent length of segment 3 | m |
| \(L_e\) | Total equivalent length in diameter D₁ | m |
Method and standards
Equivalent length from the general flow equation.
Where it is used
- Lines with wall-thickness or diameter changes.
- Adding a smaller lateral to a model.
Common mistakes
- Applying it where the flow changes along the line.
Assumptions and limits
- Same flow and transmission factor in every segment.
References
- Menon
- Gas Pipeline Hydraulics (CRC Press, 2005)
- ch. 3.6
- eqs. 3.1–3.6
Questions and answers
Why the fifth power of diameter?
In the general flow equation P₁² − P₂² is proportional to L/D⁵ at a fixed flow and transmission factor.
Can I use it with deliveries between segments?
No; with different flows in each segment, work segment by segment.
What do the defaults represent?
Three segments: 16 km of 393.7 mm, 24 km of 342.9 mm and 16 km of 292.1 mm bore (NPS 16, 14 and 12).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.