FireCADCalc

Parallel Gas Pipe Loops: Flow Split and Equivalent Diameter

Flow through each of two parallel gas pipe loops of different length and bore, and the equivalent single-pipe diameter, from the general flow equation.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserFuel oil and gas system

Inputs

Examples: 100 MMSCFD in NPS 14 (24 mi) and NPS 12 (16 mi) loopsEqual loops

Results

Both loops start and end at the same points, so they share the pressure drop; the same transmission factor and gas temperature are assumed in both.

Flow through loop 11,444,281m³/d
Flow through loop 21,387,404m³/d
Equivalent diameter over length L₁448.87mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 MMSCFD in NPS 14 (24 mi) and NPS 12 (16 mi) loops. The inputs, in the units selected above:

InputValue
Total flow (any basis)2,831,685 m³/d
Length of loop 138.624 km
Inside diameter of loop 1342.90 mm
Length of loop 225.750 km
Inside diameter of loop 2311.15 mm

Applying the formula below gives:

ResultValue
Flow through loop 11,444,281 m³/d
Flow through loop 21,387,404 m³/d
Equivalent diameter over length L₁448.87 mm

Open this example in the calculator and change any input.

Formula

\(\frac{Q_1}{Q_2} = \left(\frac{L_2}{L_1}\right)^{0.5}\left(\frac{D_1}{D_2}\right)^{2.5}, \quad D_e = D_1\left(\frac{Q}{Q_1}\right)^{0.4}\)

Variables

Symbol Meaning SI unit
\(Q\) Total flow (any basis) m³/s
\(L_1\) Length of loop 1 m
\(D_1\) Inside diameter of loop 1 m
\(L_2\) Length of loop 2 m
\(D_2\) Inside diameter of loop 2 m
\(Q_1\) Flow through loop 1 m³/s
\(Q_2\) Flow through loop 2 m³/s
\(D_e\) Equivalent diameter over length L₁ m

Method and standards

Equal pressure drop in both loops.

Where it is used

  • Debottlenecking with a loop.
  • Twin lines between stations.

Common mistakes

  • Mixing base and actual flows.
  • Loops that do not share both ends.

Assumptions and limits

  • Same F and temperature in both loops.

References

  • Menon
  • Gas Pipeline Hydraulics (CRC Press, 2005)
  • ch. 3.7
  • eqs. 3.10–3.17

Questions and answers

Why loop a pipeline?

A parallel loop over a bottleneck section lowers the pressure drop there, raising capacity without a new compressor.

Does the shorter loop carry more gas?

Yes, and the larger one too: flow goes as D^2.5/√L.

What do the defaults represent?

Menon's Example: 100 MMSCFD split between a 24-mile NPS 14 loop and a 16-mile NPS 12 loop (about 51 and 49 MMSCFD in his example, which uses slightly different bores).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.