Worked example
Example: 100 m3 wort, 6 %/h, 60 min. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wort volume | 100.00 m³ |
| Wort density | 1,040.0 kg/m³ |
| Wort specific heat | 3.9500 kJ/(kg·K) |
| Wort temperature into the kettle | 72.000 °C |
| Evaporation per hour (share of the wort mass) | 6.0000 % |
| Boil time | 60.000 min |
| Steam pressure (absolute) | 4.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated | 6.2400 t |
| Heat (heat-up + evaporation) | 25.573 GJ |
| Steam | 11.987 t |
Open this example in the calculator and change any input.
Formula
\(E = V\rho\,e\,t_b, \quad Q = V\rho c_p(T_b - T_1) + E\,h_{fg}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Wort volume | m³ |
| \(\rho\) | Wort density | kg/m³ |
| \(c_p\) | Wort specific heat | J/(kg·K) |
| \(T_1\) | Wort temperature into the kettle | K |
| \(e\) | Evaporation per hour (share of the wort mass) | - |
| \(t_b\) | Boil time | s |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(E\) | Water evaporated | kg |
| \(Q\) | Heat (heat-up + evaporation) | J |
| \(m_s\) | Steam | kg |
Method and standards
Heat-up and evaporation balance.
Where it is used
- Brewhouse steam budgets.
Common mistakes
- Using total evaporation per brew as per hour.
Assumptions and limits
- Atmospheric boiling at sea level (1 atm), whatever the site altitude; no kettle heat losses or heating-surface inefficiency, so the steam is a minimum.
- The evaporation rate is a share of the wort mass (V ρ) per hour. A rate quoted as a share of hot wort volume gives a water mass about 4 % lower (water is less dense than wort).
References
- Mass and energy balances (definitions)
- Steam and water properties from IAPWS-IF97
Questions and answers
What evaporation rate is usual?
4–8 % of the volume per hour; older kettles 8–10 %.
Why boil at all?
Sterilisation, hop isomerisation, protein coagulation and driving off DMS.
Is the boiling point 100 °C?
About 100 °C at sea level; the calculator uses water at 1 atm.