Worked example
Example: 80 → 145 °C with 10 bar steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Product flow | 10,000 kg/h |
| Product specific heat | 3.9000 kJ/(kg·K) |
| Preheat temperature | 80.000 °C |
| UHT temperature | 145.00 °C |
| Steam pressure (absolute) | 10.000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam injected | 1,170.1 kg/h |
| Water added (share of product) | 11.701 % |
| Flash vessel temperature that removes the added water (equals the preheat temperature) | 80.000 °C |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{\dot M c_p (T_2 - T_1)}{h_g(p_s) - h_f(T_2)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot M\) | Product flow | kg/s |
| \(c_p\) | Product specific heat | J/(kg·K) |
| \(T_1\) | Preheat temperature | K |
| \(T_2\) | UHT temperature | K |
| \(p_s\) | Steam pressure (absolute) | Pa |
| \(\dot m_s\) | Steam injected | kg/s |
| \(\Delta w\) | Water added (share of product) | - |
| \(T_f\) | Flash vessel temperature that removes the added water (equals the preheat temperature) | K |
Method and standards
Direct-contact heat balance with IF97.
Where it is used
- UHT plant design.
- Steam budgets.
Common mistakes
- Ignoring that injected steam dilutes the product.
- Using indirect heating figures.
Assumptions and limits
- Complete condensation; no losses.
- With equal specific heat and latent heat in the injection and the flash, the flash vessel must return the product to the preheat temperature to remove exactly the water added; the output repeats the preheat temperature.
References
- Mass and energy balances (definitions)
- Steam and water properties from IAPWS-IF97
Questions and answers
Why does the vacuum cooler return to preheat temperature?
Flashing to the same temperature removes the condensed steam, so the product's solids are unchanged.
How much water is added?
About 10–12 % for 80 → 145 °C.
Why culinary steam?
It contacts food: filtered, from treated feedwater without non-food amines.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.