FireCADCalc

Ice Cream Continuous Freezer Refrigeration Load

Refrigeration load of a continuous ice cream freezer from mix flow, temperatures, water content, ice fraction at draw and dasher heat.

Food, dairy and textile

Inputs

Examples: Illustrative 600 kg/h freezerLarge 2000 kg/h lineSorbet, high water

Accepted: 0.36 to 36,000 kg/h
Accepted: -5 to 20 °C
Accepted: -10 to 0 °C
Accepted: -20 to 0 °C
Accepted: 30 to 90 %
Accepted: 0 to 90 %
Accepted: 2 to 4 kJ/(kg·K)
Accepted: 1.5 to 3.5 kJ/(kg·K)
Accepted: 0 to 50 %

Results

The freezer cools the mix to its initial freezing point, freezes part of its water (about half at a draw temperature of −5 to −6 °C) and cools it further, while the dashers and scraper blades add mechanical heat. The latent heat of the ice formed is the largest part. The rest of the water freezes later in the hardening tunnel, which has its own load.

Sensible heat above freezing21.450kJ/kg
Latent heat of the ice formed103.42kJ/kg
Sensible heat below freezing7.5000kJ/kg
Refrigeration load25.370kW
Load in tons of refrigeration7.2139TR

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 600 kg/h freezer. The inputs, in the units selected above:

InputValue
Mix flow600.00 kg/h
Mix inlet temperature4.0000 °C
Initial freezing point of the mix-2.5000 °C
Draw temperature-5.5000 °C
Water content of the mix62.000 %
Share of the water frozen at draw50.000 %
Specific heat of the unfrozen mix3.3000 kJ/(kg·K)
Specific heat of the partly frozen mix2.5000 kJ/(kg·K)
Dasher and friction heat as a share of the product heat15.000 %

Applying the formula below gives:

ResultValue
Sensible heat above freezing21.450 kJ/kg
Latent heat of the ice formed103.42 kJ/kg
Sensible heat below freezing7.5000 kJ/kg
Refrigeration load25.370 kW
Load in tons of refrigeration7.2139 TR

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m\left[c_l(T_{in} - T_{fp}) + x_w f_i L_f + c_f(T_{fp} - T_d)\right](1 + f_d)\)

Variables

Symbol Meaning SI unit
\(\dot m\) Mix flow kg/s
\(T_{in}\) Mix inlet temperature K
\(T_{fp}\) Initial freezing point of the mix K
\(T_{d}\) Draw temperature K
\(x_w\) Water content of the mix -
\(f_i\) Share of the water frozen at draw -
\(c_l\) Specific heat of the unfrozen mix J/(kg·K)
\(c_f\) Specific heat of the partly frozen mix J/(kg·K)
\(f_d\) Dasher and friction heat as a share of the product heat -
\(q_s\) Sensible heat above freezing J/kg
\(q_l\) Latent heat of the ice formed J/kg
\(q_f\) Sensible heat below freezing J/kg
\(\dot Q\) Refrigeration load W
\(\dot Q_{TR}\) Load in tons of refrigeration W

Method and standards

Freezer load.

Where it is used

  • Ice cream plant refrigeration design.
  • Checking freezer capacity.

Common mistakes

  • Ignoring dasher heat.
  • Freezing all the water in the freezer.

Assumptions and limits

  • Steady flow; mean specific heats.

References

  • Refrigeration load of continuous ice cream freezing
  • Tetra Pak
  • Dairy Processing Handbook (Tetra Pak Processing Systems, Lund)

Questions and answers

How much refrigeration does a 600 kg/h freezer need?

About 25 kW (7 TR) with the defaults.

Why only half the water frozen?

At −5 to −6 °C the remaining water holds enough dissolved sugar to stay liquid; hardening freezes more.

What do the defaults represent?

An illustrative 600 kg/h of mix from 4 °C, freezing point −2.5 °C, drawn at −5.5 °C with half its water frozen.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.