Worked example
Example: Illustrative 10000 L/h at 200 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Product flow | 10,000 L/h |
| Total homogenising pressure (both stages) | 200.00 bar |
| Product density | 1,030.0 kg/m³ |
| Product specific heat | 3.9000 kJ/(kg·K) |
| Pump and drive efficiency | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic power | 55.556 kW |
| Motor power | 69.444 kW |
| Temperature rise of the product | 4.9788 K |
| Energy per 1000 L | 6.9444 kWh |
Open this example in the calculator and change any input.
Formula
\(P_h = \dot V\Delta p, \quad P_m = \frac{P_h}{\eta}, \quad \Delta T = \frac{\Delta p}{\rho c_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Product flow | m³/s |
| \(\Delta p\) | Total homogenising pressure (both stages) | Pa |
| \(\rho\) | Product density | kg/m³ |
| \(c_p\) | Product specific heat | J/(kg·K) |
| \(\eta\) | Pump and drive efficiency | - |
| \(P_h\) | Hydraulic power | W |
| \(P_m\) | Motor power | W |
| \(\Delta T\) | Temperature rise of the product | K |
| \(e\) | Energy per 1000 L | J |
Method and standards
Homogeniser.
Where it is used
- Dairy, juice and emulsion plants.
- Motor sizing and heat balance.
Common mistakes
- Forgetting the temperature rise in the heat balance.
- Using the first-stage pressure only.
Assumptions and limits
- All hydraulic power dissipated in the product.
References
- Hydraulic power of a positive-displacement homogeniser
- Tetra Pak
- Dairy Processing Handbook (Tetra Pak Processing Systems, Lund)
Questions and answers
How much does homogenising warm milk?
About 2.5 K per 100 bar: 200 bar raises it by about 5 K.
How big is the motor for 10,000 L/h at 200 bar?
About 69 kW at 80 % efficiency.
What do the defaults represent?
An illustrative 10,000 L/h milk homogeniser at 200 bar total with 80 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.